Flotec FPCI3350 Manual Del Usuario página 3

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation
Installation
10" Min. with
Vertical Switch
16" Min. with
Tethered Switch
1. Install pump in sump pit with minimum diameter
of 10" (254mm) for models equipped with vertical
switches and 14" (356mm) for tethered float switch
models. Sump depth should be 16" (406mm) for
tethered models and 10" (254mm) for vertically
switched models. Construct sump pit of tile, concrete,
steel or plastic. Check local codes for approved
materials and for proper installation.
2. Install pump in pit so that switch operating
mechanism has maximum possible clearance.
3. Pump should not be installed on clay, earth or sand
surfaces. Clean sump pit of small stones and gravel
which could clog pump. Keep pump inlet screen clear.
NOTICE Do not use ordinary pipe joint compound on
plastic pipe. Pipe joint compound can attack plastics.
4. Install discharge plumbing. Use rigid plastic pipe and
wrap threads with PTFE pipe thread sealant tape.
Screw pipe into pump hand tight plus 1-1/2 turns.
Risk of flooding. Can cause personal injury
and/or property damage. If a flexible discharge hose is
used, make sure pump is secured in sump to prevent
movement. Failure to secure pump may allow pump
movement, switch interference and prevent pump from
starting or stopping.
For parts or assistance, call Flotec Customer Service at
10" Minimum
with Vertical Switch
14" Minimum
with Tethered Switch
Sump Pit
Hard Surface –
No Sand, Clay,
Gravel
4824 0205
4827 0205
5. To reduce motor noise and vibrations, a short length
of rubber hose (1-7/8" (47.6mm) I.D., e.g. radiator
hose) can be connected into discharge line near pump
using suitable clamps.
6. Install an in-line check valve or an in-pump check
valve to prevent flow backwards through pump when
pump shuts off.
NOTICE If your check valve is not equipped with an
air bleed hole to prevent airlocking pump, drill a 1/8"
(3.2 mm) hole in discharge pipe just above where the
discharge pipe screws into the pump discharge. Be sure
the hole is below the waterline and the check valve to
prevent air locks.
7. Power Supply: Pump is designed for 115 V., 60 Hz.,
operation and requires a minimum 15 amp individual
branch circuit. Both pump and switch are supplied
with 3-wire cord sets with grounding-type plugs.
Switch plug is inserted directly into outlet and pump
plug inserts into opposite end of switch plug.
Risk of electric shock. Can shock, burn or
kill. Pump should always be electrically grounded to a
suitable electrical ground such as a grounded water pipe
or a properly grounded metallic raceway, or ground wire
system. Do not cut off round ground pin.
1-800-365-6832
3
4825 0205
4828 0205

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fpci5050

Tabla de contenido