3. Unplug the charger and remove the batteries from the charger when not in use.
Begin again at Step 1 to charge the next set of batteries.
Discharging Instructions
1. Follow steps 1 – 3 from the "Charging Instructions".
2. The LCD will indicate the discharging status and the word "Discharging" will be displayed (the blue
backlight will light up during the discharging process). The 4 battery icons will keep flashing until all
the batteries have been discharged.
Note: The discharge process will not function when you press the "discharge button" more than 1
minute after the charging process started.
After the batteries are fully discharged, charging process will be started automatically.
Bad Cell Detection
When the charge process is started, the charger does check the health status of each battery. If one or
more batteries are unsuitable for charging because of short circuit or reversed polarity, the word "BAD"
will be displayed on the LCD screen and the "battery icon" will flash.

Technical Data:

Charge Current:
AAA size: 500mA
AA size: 1300mA
C size: 1300mA
D size: 1300mA
9V size (PP3): 30mA
Discharge current:
AA, AAA, C, D
Detection method
Suitable battery types / capacities:
* Charge time will vary depending upon the brand, capacity and condition of batteries being charged.
USB:
The USB socket will be ready for use only when charging is completed or there is no battery in the
charger compartment.
The "USB function indicator" will be displayed on the LCD when the USB socket is ready for use.
Note: Make sure the load does not exceed 500 mA for the USB socket.

Important Safety Instructions

• Before charging, read the instructions.
• This charger is intended for use with nickel-metal-hydride rechargeable batteries only. Attempting to
charge other types of batteries may cause personal injury and/or damage to the charger.
• Do not charge non-rechargeable batteries.
• Do not expose the charger to rain or moisture.Suitable for indoor use only.
• Remove the power supply from the wall socket when the charger is not in use.
Ni-MH Example
AAA 1000 mAh
AA 2500 mAh
C 2800 mAh
D 2800 mAh
150 mAh
400mA
-ΔV auto cut-off for AAA, AA, C, D size batteries
AAA
AA
C
D
9 V
3
Charging Time
2 hours
2 hours
2 ¼ hours
2 ¼ hours
5 hours
500-1100 mAh
1300-2700 mAh
1300-4500 mAh
1300-9000 mAh
150-250 mAh