1.0 Specifications

Mains voltage
Mains frequency
Welding steps
Current Range
Stepless at 220/240 V
Stepless at 380/415 V
Max. OCV
at 220 - 240 V
Max. OCV at 380 - 415 V
Max. input cap. at 220 - 240 V 4.3 kVA
Max. input cap. at 380 - 415 V 11.8 kVA
Working voltage
Cos - 220 - 240 V
Cos - 380 - 415 V
Duty cycle at max.
output 220 - 240 V* (25 / 40°) 25 %/ 17 %
100% duty cycle 220 - 240 V*
(25 / 40°)
Duty cycle at max.
output 380 - 415 V* (25 / 40°) 5 %/ 3 %
100% duty cycle 380 - 415 V*
(25 / 40°)
Mains fuse 220 - 240 V
Mains fuse 380 - 415 V
Cooling
Insulation class
Protection class
Dimensions (lxwxh) in mm
Weight
Accessory kit no.
Max. electrode diameter

2.0 Putting A Single-Phase Machine Into Operation

- This welding machine should be connected to the power source via an Earth Fault Circuit Interrupter with 30 mA
capacity.
- Have worn or damaged power cables replaced immediately by a qualified electrician.
Do not operate the welding machine with a damaged power cable, danger of personal injury through electric shock.
- Children under the age of 16 should not operate this welding machine.
Connect to an earthed, single-phase 220 - 240 V outlet on a circuit protected by a 16 A time-lag fuse. Double insulated
machines (with PVC housing) do not require an earthed outlet. Operating other electrical machines or appliances on
the same circuit while welding is not recommended.
If your machine has detachable welding and earth cables, connect cables to the sockets, lock by turning plug clockwise.
With transformers the polarity does not matter, so both cables can be connected to either the + or - sockets. The same
applies for machines with permanently attached earth and welding cables.
Attach earth clamp to the work piece, close to the area to be welded and on to bare metal for good conduction. Place
a stick electrode into the electrode holder.
Set current selector switch to desired current. On all machines with stepless setting turn crank or handwheel until
desired current is indicated (stepless).
If there is no power outlet near the work piece an extension cable is required. The cable lead cross section must be
2
at least 2.5 mm
. The extension cable should be fully uncoiled to prevent heat build-up by inductance. Inductance also
considerably reduces the welding current. Extending the welding cables is also possible, however the cross section
of the extension cable should be larger than that of the cable supplied with the machine. Every machine is overload
protected by a thermo switch, which switches the transformer off if it becomes too hot. Let cool down until machine
switches on automatically. Some machines are equipped with a fan to increase the duty cycle through forced cooling.
The fan operates as long as the machine is switched on.

2.1 Putting A combination 1-Ph/2-Ph Machine Into Operation

All "Combi" machines are supplied with a plug (CEE 5 pin 16/32 A) installed on the power cable. Connect to a 220 - 240 V
single-phase outlet with the adaptor supplied or to two phases of a 380/415 V 3-phase mains.
SK 200
SK 230
220 - 240 V
220 - 240 V
380 - 415 V
380 - 415 V
50 H
50 Hz
stepless
stepless
25-200 A
25-230 A
25-110 A
25-114 A
40-200 A
40-230 A
36.5 - 39 V
37.0 - 40 V
48.5 - 55 V
53.0 - 59 V
4.5 kVA
13.7 kVA
21.0-28.0 V
21.0-28.8 V
0.77 (110 A)
0.77 (114 A)
0.66 (200 A)
0.63 (220 A)
25 %/ 17%
55 A/ 35 A
60 A/ 40 A
5 %/ 3 %
-
-
16 A time-lag
16 A time-lag
25 A time-lag
25 A time-lag
self
self
F
F
IP 21
IP 21
440x230x430
440x230x430
27 kg
31 kg
7
8
5 mm
5 mm
SK 260
SB 200
220 - 240 V
220 - 240 V
380 - 415 V
380 - 415 V
50Hz
50Hz
stepless
stepless
25-260 A
20-200 A
25-120 A
20-110 A
40-260 A
30-200 A
36.0 - 40 V
36.5 - 39 V
55 - 60 V
48.5 - 55 V
4.4 kVA
4.3 kVA
16.4 kVA
11.8 kVA
21.0-30.2 V
21.0-28.0 V
0.80 (120 A)
0.77 (110 A)
0.62 (260 A)
0.67 (200 A)
25 %/ 17%
20 %/ 15 %
55 A/ 35 A
50 A/ 35 A
5 %/ 3 %
5 %/ 3 %
-
-
16 A time-lag
16 A time-lag
35 A time-lag
20 A time-lag
self
self
F
F
IP 21
IP 21
440x230x430
550x330x380
35 kg
40 kg
8
130
5 mm
5 mm
SB 230
SB 260
220 - 240 V
220 - 240 V
380 - 415 V
380 - 415 V
50Hz
50 Hz
stepless
stepless
20-230 A
30-260 A
20-114 A
30-135 A
36-230 A
75-260 A
37.0 - 40 V
39.0 - 40 V
53.0 - 59 V
55.0 - 60 V
4.5 kVA
4.5 kVA
13.7 kVA
16.4 kVA
21.0-28.8 V
21.0-30.2 V
0.77 (114 A)
0.8 (130 A)
0.63 (220 A)
0.62 (260 A)
55 %/ 40 %
50 %/ 35 %
85 A/ 60 A
90 A/ 65 A
20 %/ 15 %
10 %/ 1,5 %
-
90 A
16 A time-lag
16 A time-lag
25 A time-lag
35 A time-lag
fan
fan
F
F
IP 21
IP 23
550x330x380
550x330x380
44 kg
44 kg
8
8
5 mm
5 mm