AVENTICS | LS04 | R412008224–BDL–001–AB | English
English
1
About this document
These instructions contain important information on the
safe and appropriate extension of the LS04 valve system.
Read these instructions before working with the LS04
valve system.
Keep these instructions in a location where they are
accessible to all users at all times.
Signal words and their meaning
Observe the safety instructions and warnings.
Indicates a hazardous situation which, if not
avoided, could result in minor or moderate injury.
Related documents
VS LS04 operating instructions
Technical data and information in accordance with the
main catalog
2
For your safety
Intended use
Use the LS04 valve system only for the purpose specified
in the operating instructions.
The intended use of the LS04 valve system and its
extensions also requires that
you comply with these instructions,
you comply with all accompanying documents,
you comply with national accident prevention
regulations at the site,
expansions are only carried out by qualified and
trained specialists.
General safety instructions
Before working on the system, switch off the pressure
and voltage.
Before installing the valve system, check whether the
tie rods (14, 15) have been completely screwed into the
EP end plate (1).
Make sure the seals (9) have been inserted correctly.
3
Delivery contents
Extension kit for 1 valve position:
– 2x tie rod extension
– 1x cable channel segment
– Assembly instructions
oder
CAUTION
Extension kit for 2 valve positions:
– 2x tie rod extension
– 2x cable channel segment
– Assembly instructions
4
Device description
The valve system LS04 consists of the following
components (see fig.
1
1 EP end plate (variants: IP50 top, IP20 top, IP20 side)
with integrated D-SUB plug
2 Blanking plate
3 Supply/partition plate
4 Cable channel
5 Tie rod extension
6 1 to 12 valve plates, bistable or
1 to 24 valve plates, monostable
7 Cable channel segment
8 Guide for centering pin
9 Seals
10 P end plate
11 Cylinder screws with hexagon socket
12 Lower tie rod guide
13 Upper tie rod guide
14 Lower tie rod
15 Upper tie rod
16 Cable loop with plug-in connection
5
Equipment variants
The valve system LS04 can be equipped with mono-stable
and bistable subbases. A maximum of 24 valve solenoids
can be controlled. The following combinations are
possible:
Max. 24 valve plates, mono-stable
Max. 12 valve plates, bistable
Combination of mono-stable and bistable valve plates
Mixed configurations of bistable and mono-stable
valves are possible.
Maximum configurations see fig.
Important notes on equipment
With mixed components, first assemble the valve
plates with bistable valves and then those with mono-
stable valves, starting at the EP end plate.
Note the marking of the valve plates (1) and valve
positions (2) with mono-stable or bistable valves (see
3
fig.
).
If a mono-stable valve is installed on a bistable valve
position, the corresponding connection for solenoid 12
remains unused.
):
3
.
3