ENGLISH
system have not been activated. Both these manual manoeuvre systems
are equipped with safety microswitches which, if activated, block any elec-
trical command.
To adjust the end of the stroke proceed as follows:
- Close the door manually, keeping it slightly raised above the ground.
- Identify the closing microswitch according to the installation position of
the gearmotor (fig. 10).
- The protection wedge "P" which places the limit switch drive (fig.9) in neu-
tral.
-Remove it and throw it away only when adjusting the limit switch
cam.
- Lift the holding spring from the cam teeth using a screwdriver (fig.10).
- Turn the cam in the direction of the closing microswitch until the triggering
of the first limiting microswitch can be heard.
- Lower the spring until it engages with a cam tooth.
- Supply the system with power and give the start command to carry out
the opening manoeuvre.
WARNING: If the motor rotates in the opposite direction, then vary the
connections as follows:
- In the single-phase version (fig. 6A-B), invert the two connections in the
power supply terminals of the motor "M1-M2".
- In the three-phase version (fig. 6C-D), invert two phases in the power sup-
ply terminals of the motor "U-V-W".
- Give the stop command when the door is near to the opening end-of-
stroke stop.
- Disconnect the power supply and lift the holding spring from the cam
teeth using a screwdriver (fig. 9-10).
- Turn the cam in the direction of the microswitch until the first triggering of
the opening limiting microswitch can be heard.
- Lower the spring until it engages with a cam tooth.
- If the door stops during opening, keep trying to move the cam manually
until complete opening is obtained.
- Check that opening and closing stops are carried out without traction or
compression of the sectional door.
- Repeat the complete opening and closing manoeuvre a few times to
check whether the limiting microswitches are activated correctly. If this is
not the case, adjust the position of the cams as necessary.
- Whenever end-of-stoke adjustments are carried out, the cam holding
spring must always be replaced in the teeth of the two adjustment cams.
- Re-fit all the parts which were previously removed for adjustment of the
limit switches.
12) EMERGENCY MANOEUVRE (Fig.8)
In the case of electric power failure, the door remains locked in the position
it is found at.
Depending on the version installed, the manual manoeuvre is carried out
as follows:
ULISSE-C
Use the appropriate chain to open/close the door. No operation is needed
to reset the operator.
ULISSE-CM
Use the appropriate chain to open/close the door.
When the door needs to be released for maintenance, pull the cord by means
of the green knob.This disengages the motion drive from the door cable-winder
shaft.This way the door can be manoeuvred manually.To reset motor-driven
operation, pull the cord with the red knob. It may be necessary to help the
door catching on by moving it manually by a few centimetres.
ULISSE-SB
Activate the release mechanism by pulling the cord with the green knob.
This disengages the operator from the door, which can be manoeuvred
manually. To reset motor-driven operation, pull the cord with the red knob.
It may be necessary to help the door catching on by moving it manually by
a few centimetres.
Important note: The door must be perfectly balanced and allow manual
manoeuvre to be carried out easily.
13) OPERATOR CHECK
Before the operator finally becomes operational, scrupulously check the
following:
Check that all the components are tightly fastened.
Check that all the safety devices (limit microswitches, photocells, safety
edges etc.) operate correctly.
Check that the safety edge antisquashing force stops the system within
the limits provided for by the current standards.
Check the emergency manoeuvre control.
Check the opening and closing operations by means of the control devices fitted.
Check the electronic logic for normal and customised operation, if a
control panel is installed.
14 -
ULISSE - Ver. 05
INSTALLATION MANUAL
14) OPERATOR USE
Since the operator can be controlled remotely by means of a radio transmit-
ter or Start button, and therefore out of sight, all the safety devices must be
regularly checked for perfect efficiency.
In the case of any malfunction, request prompt assistance from qualified
personnel.
Children must be kept at a safe distance from the operator working area.
15) CONTROL
The use of this operator allows the door to be opened and closed automatically.
There are different types of control (manual, radio transmitter, magnetic card
access etc.), depending on the installation requirements and characteristics.
See the relevant instructions for the various control systems.
The operator users must be instructed on control and use.
16) MAINTENANCE
Before carrying out any maintenance, disconnect the power supply.
Periodically check if there are any oil leaks from the reduction gear.
Periodically check the motion drive system and lubricate as necessary
(only for reduced chain drive).
Check all the door and operator safety devices.
When any operation malfunction is found, and not resolved, disconnect
the power supply and request the assistance of a qualified technician
(installer). When the operator is out of service, activate the emergency
release device in order to allow the door to be opened and closed manu-
ally.
17) DISMANTLING
WARNING! This operation should only be carried out by qualified person-
nel.
In the case where the operator is disassembled to be reassembled on another
site, proceed as follows:
Disconnected it from the power supply and the electrical installation.
In the case where some of the components cannot be removed or are
damaged, they must be replaced.
WARNINGS
Correct controller operation is only ensured when the data contained in
the present manual are observed.The company is not to be held respon-
sible for any damage resulting from failure to observe the installation
standards and the instructions contained in the present manual.
The descriptions and illustrations contained in the present manual are
not binding. The Company reserves the right to make any alterations
deemed appropriate for the technical, manufacturing and commercial
improvement of the product,while leaving the essential product features
unchanged, at any time and without undertaking to update the present
publication.features unchanged, at any time and without undertaking
to update the present publication.

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido