TECHNICAL DATA

VCP 170 E
Vacuum cleaner for wet and dry -
Original instruction
Power consumption / Socket connection
rating
EU (230 V, 50 Hz)) ..........................
............................................. 400-1200 W / 2400 W
CH, DK (230 V, 50 Hz) .....................
............................................. 400-1200 W / 1100 W
GB (240 V, 50 Hz) ...........................
............................................. 400-1200 W / 1800 W
AUS (240 V, 50 Hz) .........................
............................................. 400-1200 W / 1200 W
Vacuum ............................................
........ 24.000 Pa .................24.000 Pa ............ 24.000 Pa .............. 24.000 Pa
Delivery rate (without suction hose) .....
.......... 3.700 l/min .............. 3.700 l/min ........... 3.700 l/min ............3.700 l/min
Filter surface area .............................
.......... 4.600 cm² ................ 3.600 cm² ............ 4.600 cm² ..............3.600 cm²
Tank capacity ....................................
...............17 Liter .................... 17 Liter.................32 Liter ................. 32 Liter
Suction hose .....................................
. ø 27 mm x 3,5 m ............. ø 27mm x 3,5 m .........ø 27 mm x 3,5 m .......... ø 27 mm x 3,5 m
Noise level to EN 60704-1 ..................
................. 74 dB(A) .......................72 dB(A) ..................74 dB(A) ................... 72 dB(A)
Dimensions .......................................
445x380x485 mm ........445x380x485 mm ... 550x380x485 mm .... 550x380x485 mm
Weight .............................................
..............9,4 kg ...................... 9,4 kg ..................9,9 kg ................... 9,9 kg
Length of mains lead ..........................
..............5,5 m ....................... 7,5 m ...................5,5 m .................... 7,5 m
Protection class .................................
.................I ............................. I ......................... I ...........................I
Protection type ..................................
...........IP X4 ....................... IP X4 ...................IP X4 .................... IP X4
The noise level when working can
exceed 85 dB (A). Wear ear protectors!
USE
Please read the instructions on pages 3-14
SPECIAL SAFETY INFORMATION
This machine can only be operated safely when the
operating instructions and the pamphlet containing
the safety instructions have been completely read
and strictly adhered to.
Always inspect cable and plug before using machine.
Only have damage repaired by a qualified
professional.
Make sure machine is switched off before inserting
plug in socket.
The plug socket on the appliance may be used only
for the purposes defined in the usage instructions.
If the mains connection cable is damaged the
machine must not be used.
Make sure that the mains connection cable is not
damaged, squashed, bent, or damaged by being run
over or in any other way.
Extension cables to the mains must at least be
protected from water spray and contain an earth
lead.
The appliance must be connected to a cable that is
protected by a circuit breaker or a fusible insert with
the following minimum current strength.
CH, DK, AUS: 10 A
GB: 13 A
EU: 16 A
The appliance may only be used in a room that has
adequate ventilation (comply with national safety at
work regulations).
Comply with the applicable safety regulations of the
material manufacturer when vacuuming.
Do not vacuum any inflammable or explosive fluids
(for example petrol, alcohol, thinners, solvents, etc.)
– Risk of explosion.
Do not suck in any combustible or explosive dusts
(e.g. magnesium, aluminium etc.) - Danger of
explosion!
Do not vacuum any sparks or hot parts (for example
metal chips, ash, etc.) whose temperature exceeds
60°C – Risk of explosion and fire.
Do not vacuum any aggressive fluids or solids
(acids, lyes, solvents, etc.).
18
ENGLISH
VCP 171 E-L
VCP 320 E
VCP 321 E-L
You are not allowed to use the appliance in the
vicinity of inflammable gases or substances.
Do not put appliances or accessories into operation,
if: the appliance has recognizable damage (cracks/
breaks), the mains connection lead is defective or
shows signs of cracking or aging, there is a
suspected non-visible defect (after having been
dropped).
CAUTION! If any foam or water egresses, switch off
immediately. Empty the container and, if need be,
the pleated filter.
Acids, acetone and solvents can corrode the
appliance components.
In the event of misuse, improper operation or
unprofessional repair work no liability shall be
assumed by us for any damage incurred.
Not suitable for sweeping up liquids which form a
large foam.
CAUTION! This device must not be used or stored
outdoors in wet conditions.
The power supply cord may only be replaced with
one of the following type:
VCP 170 E, VCP 320 E: H05 VV-F
VCP 171 E-L, VCP 321 E-L: H05 RR-F.
CAUTION! The device contains noxious dust.
Emptying and maintenance procedures,
including the removal of dust collectors, may
only be carried out by trained personnel wearing
appropriate protective gear. Do not operate
without complete filtration system.
Before using the device, users must be given
information on the use of the device and on how to
handle and dispose of the hazardous substances for
which the device is intended to be used.
When emptying or cleaning the device or changing
the filter, personnel must be wearing suitable
equipment to protect them from the harmful
substances. Before this work is undertaken the
device must be decontaminated. The rooms in which
these procedures are carried out must have a local
exhaust ventilation system and the area must be
cleaned afterwards in accordance with regulations.
When carrying out maintenance and repair work it is
necessary to dispose of any contaminated objects
which cannot be adequately cleaned. Such objects
must be placed in impermeable bags in compliance
with the relevant regulations for the disposal of such
refuse.
IMPORTANT. Do not use without the complete
filtration system.
INTENDED USE
VCP 170 E, VCP 320 E: These vacuum cleaners are
designed for vacuuming non-hazardous dust, dirt,
sand, chips and water.
VCP 171 E-L, VCP 321 E-L: These vacuum
cleaners are designed for vacuuming hazardous dust
in dust safety class L (maximum workplace
concentration value > 1 mg/m
) and for vacuuming
3
dirt, dirt, sand, chips and water.
This device is suitable for use on commercial
premises, e.g. hotels, schools, hospitals, factories,
shops, offices and leased businesses.
Wet filter 633583 does not meet the requirements of
dust class „L" and should only be used to absorb
liquids.
If the appliance is used for uses other than that for
which it is designed, the user accepts all liability.

MAINS CONNECTION

Ensure that the voltage of the power supply matches
the information on the type plate of the power tool.
Tools with a rating of 230 V can also be connected to
a 220 V/240 V supply.
Only connect the electric tool to the vacuum cleaner
when it is switched off.
Connect only to sockets with an earth contact.
EC-DECLARATION OF CONFORMITY
Vacuum cleaner
Serial no.
VCP 170 E
498254, 498255, 498256
498257, 498258
VCP 171 E-L
498259, 498260, 498261
498262, 498263
VCP 320 E
498264, 498265, 498266
498267, 498268
VCP 321 E-L
498244, 498269, 498270
498271, 498272
We declare under our sole responsibility that this
product is in conformity with the following standards
or standardized documents. EN 62233, EN 60335-1,
EN 60335-2-69, EN 55014-1, EN 55014-2,
EN 61000-3-2, EN 61000-3-3 in accordance with the
regulations 2006/95/EC, 2004/108/EC.
All the procedures were applied as validly amended
at the time of the issue of this declaration, without
quoting these.
Technical documentation is kept at the manufacturer.
10
Stanislav Jakeš
Environmental Protection/Disposal
Power tools, accessories and packaging should be
sorted for environmental-friendly recycling.
Only for EC countries:
Do not dispose of power tools
into household waste!
According to the European Directive 2002/96/EC on
waste electrical and elec tronic equipment and its
incorporation into national law, power tools that are
no longer suitable for use must be separately
collect ed and sent for recovery in an environmen tal-
friendly manner.
REACh
REACh is a European Chemical Directive that came
into effect in 2007. As "downstream users" and
product manufacturers, we are aware of our duty to
provide our customers with information. We have
set up the following website to keep you updated
with all the latest news and provide you with
information on all the materials used in our existing
products: http://www.tts-protool.com/reach
MAINTENANCE
Disconnect the vacuum cleaner from the mains
supply before you clean it.
If the suction power falls even after you have
cleaned the filer, the filter must be replaced (see
filter replacement section in the picture section).
CAUTION! Clean the water level demarcation and
inspect it for damage regularly.
The manufacturer or a trained person must conduct
a technical inspection of the appliance at least once
per year, which, for example, includes an inspection
of the filter for signs of damage, checking that the
appliance is air-tight and testing the safety
components (filter element).
Accessories and spare parts can be ordered from a
service outlet, quoting the part number (see
attached list). The part numbers are shown in the
tables in the picture sections.
Use only Protool accessories and spare parts.
Components whose replacement is not described
should only be replaced at a service outlet.
WARRANTY