IO-Link-Configuration
SPDU Index
Inde
Meaning
x
0x10
Vendor-ID
0x12
Device-ID
0x15
Serial number
0x16
HW number of version
0x17
SW number of version
0x18
Application Specific Name
0x90
Teach parameter for switching state 1
0x91
Teach parameter for switching state 2
0x92
Tolerance step
0x93
Tolerance level default
0x94
Teach button status
Process data
0x28
State process data
Output 1 and
Output 2
SPDU System Command
Inde
Meaning
x
0x02
Teach switching state 1
Teach switching state 2
Global Key lock
Global Key unlock
SPDU-Index-Errorcodes
Error Codes
Diagnostic data (Event data)
Meaning
Parameter changed
Communication Error
J. Schmalz GmbH
Johannes-Schmalz-Str. 1
72293 Glatten, Germany
Format/Bytes
Visible string
Visible string
Visible string
Visible string
Visible string / 4 Byte
Visible string / max. 16 Byte
UINT8, 8 Byte
UINT8, 8 Byte
UINT8, 2 Byte
UINT8, 1 Byte
UINT
UINT8, 1 Byte
Format/Bytes
UINT 8
0x1000
0x5200
0x5600
0x5800
0x80xx
0x8000
0x8023
0x8030
Mode
Type
Once
Info
Once
Error
T: +49 7443 2403-0
schmalz@schmalz.de
WWW.SCHMALZ.COM
Acces
Example
Range
s
R
J.Schmalz GmbH
R
SMAGN S051
R
123
1-2E
dez
R
1.00
R
2.33
R/W
0 ... 1023
R
0 ... 1023
R
1 ... 5
R/W
1 ... 5
R
0 ... 127
RO
128
129 ... 255
R
00
01
10
11
Access
Range
W
0xA0
0xA1
0xA3
0xA4
Remark
Communication Error
Buffer overflow
Checksum Error
Illegal SPDU
Device specific Error
No Details
Acces denied
Parameter value out of range
Remark
Instance
Error Code
Application
0x6350
Unknown
0xFF10
Remark
32
No arguments
No arguments
Button not locked
Button locked
Button not locked
Q1 and Q2 inactive
Q1 active
Q2 active
Q1 and Q2 active
Remark
Teach command for SP 1
Teach command for SP 2
Deactivates Teach button
Activates Teach button
30.30.01.00020/14 I 09/20
Page 7/14