Maintenance And Service; Filter Replacement - Hyperion IRT 3-1 PcD Manuale Di Uso E Manutenzione

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 53
9.

Maintenance and Service

Weekly
Check that all IR lamps light up during mobile dryer opera-
tion. Defect IR lamps can cause uneven heat distribution
over the surface.
Clean the dryer from dust, which can be a cause of fi re, with
a damp cloth. Also, check that all cables are undamaged. A
damaged cable can be a danger to life!
Monthly
Check the gold coated refl ectors. Damaged or extremely
dirty refl ectors can over heat the refl ector body and/or the
cassette. In case of doubt, please contact the customer
service in order to clarify if the gold coated refl ector needs
to be changed.
Yearly
Plan to change the air fi lter approx. once per year. You will
get a message in the software when it is time to change.
When starting up the dryer you will get an indication on
how much of the fi lter time that is used.
9.1

Filter replacement

Attention! The fi lters are disposable and should not be
reused.
1. Use a knife or screw driver to bend loose the two plastic
plugs at the cassette side plates.
2. Remove the used fi lter.
3. Insert the new fi lter so the IRT logo is visible from
the outside.
4. Place the long side of the fi lter opposite to the two plug
holes on the cassette according to picture.
5. Push in the fi lter until the two plugs can be
reattached.
6. Reset the fi lter timer. Log into advanced settings mode
according to chapter 8.1 and 8.2. Move to parameter 45
and press yes for reset the fi lter.
713686 rev 7
IRT 3-1 PcD, IRT 3-2 PcD and IRT 3-20 PcD
9.2
IRT lamp replacement
Attention! Do not touch either the gold coated
refl ector or the new IR lamp with your fi ngers.
Only remove the protective paper on the IR lamp
after you have installed it.
1. Disconnect power supply.
2. Loosen the three top screws on the front plate of the
cassette.
3. Disconnect the cable connector.
4. Loosen the four screws at the ends of the
refl ector and remove the refl ector from the
plate.
5. Remove the mesh and unscrew the lamp from
the two ends.
6. Install new lamps in the reverse order.
1 kW
1 kW
1 kW
9