4.3 3–pin power connection
The details below apply to MFDs that have a 3–pin
power cable.
Refer to the Connections Overview section to
establish the power connection for your MFD.
1. MFD
2. 3–pin power cable
3. Connection to power supply
4. Red cable (positive)
5. Ground (drain) wire
6. Black cable (negative)
In-line fuse and thermal breaker ratings
The following in-line fuse and thermal breaker ratings
apply to your product:
In-line fuse rating
5 A
Note:
• The suitable fuse rating for the thermal breaker
is dependent on the number of devices you are
connecting. If in doubt consult an authorized
Raymarine dealer.
• Your product's power cable may have a fitted
in-line fuse, if not then you must add an in-line
fuse / breaker to the positive wire of your
products power connection.
36
1
D13282-2
Thermal breaker rating
3 A (if only connecting one
device)
4.4 Power and data (combined)
connection
The details below apply to MFDs that have a
combined power/NMEA/video cable.
Refer to the Connections Overview section to
establish the power connection for your MFD.
4
5
3
7
6
8
1. MFD
2. Combined Power and data cable
3. Connection to vessel's 12 V / 24 V dc power
supply
4. Red cable (positive)
5. Fuse
6. Black cable (negative)
7. Video input cable
8. NMEA 0183 data cables
9. Ground (drain) wire
In-line fuse and thermal breaker ratings
The following in-line fuse and thermal breaker ratings
apply to your product:
In-line fuse rating
15 A
Note:
• The suitable fuse rating for the thermal breaker
is dependent on the number of devices you are
connecting. If in doubt consult an authorized
Raymarine dealer.
• Your product's power cable may have fitted
in-line fuse, if not then you can add an in-line
fuse to the positive wire of your products power
connection.
Power distribution
Recommendations and best practice.
• The product is supplied with a power cable. Only
use the power cable supplied with the product. Do
1
9
Thermal breaker rating
15 A (if only connecting one
device)