Thermal Camera Connection - Raymarine Lighthouse eS Serie Manual Del Usario

Tabla de contenido

Publicidad

4.20 Thermal camera connection

Thermal cameras can be connected directly to the
display's network connection or can be connected to
the SeaTalk
hs
network, via a Raymarine
switch.
2 connections are required:
• Network connection — required to control the
thermal camera via a compatible Raymarine
MFD or optional Joystick Control Unit (JCU).
• Video connection — transmits the composite
video signal to a compatible Raymarine
Note: The Thermal camera can only be connected
to MFDs with a Video input connection.
T200 Series connection
1. MFD
2. Thermal camera
3. Power over Ethernet (PoE) Injector
4. RayNet to RJ45 SeaTalk
5. Network connection to MFD (RayNet)
6. Video connection to MFD (composite video)
7. Video cable
T300 / T400 Series connection.
2
3
SeaT alk
5
8
1. MFD
2. Video connection to MFD (composite video)
Cables and connections
®
network
®
MFD.
1
4
5
hs
adaptor cable
1
4
hs
/ RayNet
6
hs
SeaT alk
/ RayNet
7
9
10
hs
SeaT alk
/ RayNet
3. Network connection to MFD (RayNet cable)
4. Raymarine
5. Video cable
6. RayNet to RJ45 SeaTalk
7. PoE (Power over Ethernet) injector (only
required if using the optional JCU)
8. Thermal camera
®
9. Joystick Control Unit (JCU), optional
10. Ethernet coupler (R32142)
Important:
• You can only view the thermal camera image on
the multifunction display to which the camera is
physically connected. If you want to view the
thermal camera image on more than 1 display
you must obtain a suitable third-party video
distribution unit.
• You can control the thermal camera using any
multifunctional display connected to the same
network. The Joystick Control Unit (JCU) is
optional, but can be used in conjunction with
multifunctional displays to control the thermal
6
camera if required.
• "Dual payload" thermal cameras include 2
independent lenses; 1 for thermal (infrared) and
7
1 for visible light. If you only have 1 display you
D12839-2
should only connect the video cable labelled
"VIS / IR" (visible light / infrared) to the display. If
you have 2 or more displays you should connect
1 cable to each display.
For further information regarding thermal camera
installation (including power connection and
mounting), refer to the installation instructions
supplied with the camera.
Thermal camera cables
Cabling requirements for thermal cameras.
Camera to network switch
A network patch cable is required to connect the
camera to the network switch. The connection is
made between the camera cable tail and the network
switch via the coupler (supplied with the camera).
Network patch cables are available in a variety of
lengths.
Joystick Control Unit (JCU)
An Ethernet (with power) cable is used to connect the
JCU. The JCU is supplied with a 1.5 m (5 ft) Ethernet
cable for this connection. If you require a different
length contact your dealer for suitable cables.
Power over Ethernet (PoE) injector to network
switch
A network patch cable is required for connecting the
PoE injector to the network switch. Network patch
cables are available in a variety of lengths.
Video cables
D12260-2
Video cables are not supplied with the product.
Please contact your dealer for suitable cables and
adaptors.
®
network switch
hs
adaptor cables
51