17. Changing the Battery

17.1 Pull off the housing and the hose sleeve (see
17.2 Remove the battery (a) by swivelling it out.
Caution!
Use only 6 V lithium battery type CRP2.
Important!
Ensure correct battery polarity when assembling.
17.3 Reassemble in the reverse order.

18. Fault Correction

Fault
Water does not flow
Water flows
continuously
Water flow too weak
Water is too hot
Water is too cold
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our customer service department!
Cause
– Battery dead (red LED lights up)
– Water-flow volume regulator closed
– Grit filters are clogged with dirt
– Cleaning clip in front of the fitting
– Electronic system in sleep mode
– Solenoid valve faulty
– Solenoid valve faulty
– Corner valves not fully opened
– Grit filters are clogged with dirt
– Aerator calcified
– Supply pressure too low
– Cold water is turned off
– Filter in cold-water part is dirty
– Hot water is turned off
– Filter in hot-water part is dirty
info@hygiene-shop.eu - www.hygiene-shop.eu
Chapter
16.).
Remedy
➯ Replace it
➯ Open it
➯ Clean them
➯ Remove
➯ Shine bright light
in front of the
sensor
➯ Replace it
➯ Replace it
➯ Open it
➯ Clean them
➯ Clean them
➯ Check it
➯ Open it
➯ Replace it
➯ Open it
➯ Replace it