11. Function
Water flow
11.1 Pull the lever upwards.
• The water will flow.
11.2 Push the lever downwards.
• The water stops flowing.
Temperature selection
12. Adjust the temperature limits
Warning!
If the hot water supply temperature is above 45°C, the temperature limits should be set.
Failure to observe this instruction can result in injuries due to scalding.
☞
The temperature limits are not an active scald protection.
12.1 Remove the stopper (a), using a screwdriver.
12.2 Loosen the grub screw (b) and remove it from the adapter (c), using a hexagonal
wrench.
12.3 Remove the lever cap (d).
12.4 Remove the housing cover (e), using a special wrench (f, see
12.5 Remove the temperature stop ring (g), using a screwdriver.
12.6 Turn the temperature stop ring and refit.
12.7 Screw down the housing cover (e), using a special wrench (f).
12.8 Slide the lever cap (d) onto the adapter (c).
12.9 Tighten the grub screw (b) to a torque of 0.8 Nm, using a hexagonal wrench.
12.10 Insert the stopper (a).
6
chapter
19.).