Replacing The Non-Return Valve; Replacing The Solenoid Valve Cartridge; Changing The Battery - Franke AQRE130 Instrucciones De Montaje Y Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21

16. Replacing the Non-return Valve

Warning!
All non-return valves must always be replaced as a group.
Failure to observe can result in an increased bacterial load in drinking water and cause a
health risk or even risk of death.
When a non-return valve is defective, the entire connector piece must be replaced. The
non-return valve is integrated in the connector piece.
16.1 Close the corner valves (c).
16.2 Trigger the valve.
16.3 Unscrew the water connector hoses (a) from the connector pieces.
16.4 Replace the connector pieces (b).
16.5 Reassemble in the reverse order.

17. Replacing the Solenoid Valve Cartridge

17.1 Close the corner valves.
17.2 Trigger the valve.
17.3 Loosen the screw (a) with a hollow hexagon wrench.
17.4 Pull the housing (b) from the base (d).
17.5 Pull off the hose sleeve (c).
17.6 Loosen the screws (f).
17.7 Remove the battery housing (e).
17.8 Remove and replace the solenoid valve cartridge (g).
17.9 Reassemble in the reverse order.

18. Changing the Battery

18.1 Pull off the housing and the hose sleeve (see
18.2 Remove the battery (a) by swivelling it out.
Important!
Use only 6 V lithium battery type CRP2.
Important!
Ensure correct battery polarity when assembling.
18.3 Reassemble in the reverse order.
Chapter
17.).
9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Aqre131Aqre13276 12982 08547576 12982 08548276 12982 085499

Tabla de contenido