excessive
voltage drop during s tart-up. Refer totheNational
Electric Code ( NEC) forinformation
onselecting theproper wire
size and securing electrical connections.
Ifyou connect additional
electrical equipment
tothe same c ircuit, consider thetotal electrical
load when s electing theproper wire size. DO NOT USE
UNDERSIZE
WIRE.
Ifwire size information
isnot a vailable,
thewire sizes s hown i nthe
following wire selection chart can beused a sasafe guide, ifthe
distance does n ot e xceed 50feet ( 15.3 m). F or l onger distances,
consult and electrical contractor
orthelocal electric company
for
recommendations.
MOTOR
SINGLE
THREE
HP
PHASE
PHASE
115V
230V
200V
230V
460V
575V
12
14
14
14
14
14
10
14
14
14
14
14
8
14
14
14
14
14
8
12
14
14
14
14
1
1.5
2
3
5
7.5
10
15
20
25
30
MAGNETIC
STARTER.
If the motor installed
on your unit has a
motor reset button,
it does not require a magnetic
starter.
If the
motor does not have this button and the unit does not have a
factory-installed
starter, install a magnetic
starter with thermal
overload
protection.
Follow the manufacturer's
instructions
for
installation.
Ingersoll-Rand
cannot accept
responsibility
for
damages
arising
from failure to provide adequate
motor protection.
FUSES.
Refer to the NEC to determine
the proper fuse or circuit
breaker
rating required.
When selecting
fuses, remember
the
momentary
starting current of an electric motor is greater
than its
full load current.
Time-delay
or "slow-blow"
fuses are recommended.
PRESSURE
SWITCH.
On units without
a factory-installed
pressure
switch, wire a pressure
switch
in accordance
with the appropriate
wiring schematic
in the DIAGRAMS
section
of this manual.
Mount
the pressure
switch in accordance
with the manufacturer's
recommendations.
The connecting
line to the receiver tank must be
as short and direct as possible,
and certified
safe for at least the
maximum
working
pressure
of the unit.
CONNECTING
A BATTERY
(GASOLINE
ENGINE
UNITS)
__
NOTE
If you will be making connections
to a remote
battery, the engine on the compressor
unit must be
equipped with an alternator.
BATTERY.
A 12 volt battery with a minimum
current rating of 250
CCA (cold cranking
amps) and minimum
ampere-hour
rating of 24
Ah should be sufficient
for cranking
most electric
start engines.
BATTERY
CABLES.
Refer to the following
table for size and length
recommendations.
Cable
Maximum
Size (CA)
Length
6
5' (1.5 m.)
4
7'-2.5" (2.1 m,)
2
12' (3.6 m.)
CONNECTION
PROCEDURES:
1.
Connect the battery positive (+) cable (A) to the starter solenoid
terminal (B).
B
/
"4
"A
2.
Connect the battery negative (-) cable (C) to the bolt shown in the
following illustration. Secure the wire in place by screwing a
suitably-sized
nut onto the bolt and down onto the terminal.
Kohler
Honda
Kawasaki
Ingersoll-Rand
3.
Connect the battery positive (+) cable (A) to the battery positive (+)
terminal.
4.
Connect the battery negative (-) cable to the battery negative (-)
terminal.
5.
Coat the terminals and cable ends with corrosion-preventive
grease.
A WARNING
Remove the cable from the negative (-) side of the
battery before servicing.
Refer to the engine manufacturer's
instructions
for more
information.
FUEL
PUMP
INSTALLATION
(GASOLINE
ENGINE
UNITS)
_
Some engines use an optional fuel pump to supply gasoline
to the
engine directly
from a vehicle's onboard fuel system.
Install the fuel
pump within 12 inches (30 cm) of the bottom surface
of the vehicle's
fuel tank. Protect the pump from contamination
by installing a fuel
isolation valve and an inline filter between
the pump fuel system.
COMPRESSOR
LUBRICATION
/k CAUTION
Do not operate without lubricant or with inadequate
lubricant. Ingersoll-Rand
is not responsible
for
compressor
failure caused by inadequate
lubrication.
SYNTHETIC
COMPRESSOR
LUBRICANT.
Ingersoll-Rand
recommends
All Season T30 Select synthetic
lubricant
from
start-up.
See the WARRANTY
section
for extended
warranty
information.
ALTERNATE
LUBRICANTS.
You may use XL-300
or a comparable
petroleum-based
lubricant
that is premium
quality, does not contain
detergents,
contains
only anti-rust,
anti-oxidation,
and anti-foam
agents as additives,
has a flashpoint
of 440°F (227°C)
or higher,
and has an auto-ignition
point of 650°F (343°C) or higher,