Vs-Fhp Pump Dip Switch Settings; Remove Pump Lid - Zodiac Jandy Pro VS FloPro Serie Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Jandy
Pro Series VS FloPro
®
To install an AquaLink
®
later) or an AquaLink PDA (Rev 4.0 or later):
1.
Remove power from the VS-FHP pump by
disconnecting the high voltage lines or by
opening any breaker to which the VS-FHP pump
power is connected.
Warning
ElECTriCal shoCK haZard
Turn off all switches and the main breaker in the
VS-FHP pump electrical circuit before starting the
procedure. Failure to comply may cause a shock
hazard, resulting in severe personal injury or death.
2.
Slide dip switches 1 and 2 down, so they are in
the OFF position. See Figure 10.
3.
Select the desired address(es) for the VS-FHP
pump by setting dip switches 3 and/or 4, as shown
in Section 3.3, VS-FHP Pump Dip Switch Settings.
4.
Connect the other end of the cable to an RS-485
connector on the AquaLink RS (or multiplexer
interface board), matching wire colors with
connector positions as follows: 1-red, 2-black,
3-yellow, and 4-green. See Figure 10.
5.
Restore power to the VS-FHP pump and verify
the operation of the controller.
6.
Refer to the appropriate manual for set up and
operation of the pump: AquaLink RS Owner's
Manual, 6593, or AquaLink PDA Owner's
Manual, H0572300.
3.3

Vs-Fhp pump dip switch settings

As shown in Figures 9 and 10, the 4-position dip switch is
located at the rear of the VS-FHP pump. This dip switch
serves two (2) functions: it selects the pump address, and
it determines what type of controller will be used with the
pump. The tables below show the dip switch settings.
switch 1
switch
Controller
2
OFF
OFF
AquaLink RS or AquaLink PDA
ON
ON
Variable Speed Controller JEP-R
switch 3 switch 4 pump address
OFF
OFF
PUMP 1
ON
OFF
PUMP 2
OFF
ON
PUMP 3
ON
ON
PUMP 4
|
Variable-Speed Pump
RS controller (Rev O or
Installation & Operation Manual
3.4

remove pump lid

1.
Make sure that the pump is turned off.
2.
Make sure that the switch to the circuit breaker
that powers the pump motor is turned off.
ElECTriCal shoCK haZard
Turn off the pump and the main breaker in the pump
electrical circuit before starting the procedure. Failure
to comply may cause a shock hazard, resulting in
severe personal injury or death.
ElECTriCal shoCK haZard
Due to the potential risk of fire, electric shock, or
injuries to persons, Zodiac® Pumps must be installed
in accordance with the National Electrical Code
(NEC), all local electrical and safety codes, and the
occupational Safety and Health Act (OSHA). Copies of
the NEC may be ordered from the National Protection
Association, 470 Atlantic Ave., Boston, MA 02210, or
from your local government inspection agency.
In Canada, Zodiac Pumps must be installed in
accordance with the Canadian Electrical Code (CEC).
4-Position
DIP Switch
Figure 10. Wiring aqualink rs Controller or
aqualink pda to Vs-Fhp pump
English
Warning
Warning
AquaLink RS
RS-485 Connectors
4 3 2 1
4 3 2 1
6 5 4 3 2 1
10 9 8 7 6 5 4 3 2 1
RS6 & RS8 ONLY
RS8 ONLY
S1
RESET
AUTO
SERVICE
HEATER
TIME OUT
S2
Connect to
AquaLink RS
4 3 2 1
RS-485 Connector
(or Multiplexer
Interface Board)
Variable-Speed
Pump
Page 13
POOL MODE
SPA MODE
SPA DRAIN
SOLAR
SPA FILL