Conduct Pressure Test - Zodiac Jandy Pro VS FloPro Serie Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Page 14
English
3.
Make sure all necessary isolation valves are
closed to prevent pool water from reaching the
pump.
4.
Following the markings on the locking ring, turn
the ring counter-clockwise until the 'START'
markings align with the ports. See Figures 11 and
12.
5.
Carefully remove the lid with locking ring.
3.5

Conduct pressure Test

Warning
When pressure testing a system with water, air is often
trapped in the system during the filling process. This air
will compress when the system is pressurized. Should
the system fail, this trapped air can propel debris at a
high speed and cause injury. Every effort to remove
trapped air must be taken, including opening the bleed
valve on the filter and loosening the pump basket lid
while filling the pump.
Warning
Trapped air in the system can cause the filter lid
to be blown off, which can result in death, serious
injury, or property damage. Be sure all air is properly
purged out of the system before operating. DO NOT
USE COMPRESSED AIR TO PRESSURE TEST OR
CHECK FOR LEAKS.
Warning
Do not pressure test above 35 PSI. Pressure
testing must be done by a trained pool professional.
Circulation equipment that is not tested properly might
fail, which could result in severe injury or property
damage.
Lid with
Locking
Ring
Seal
Figure 11. o-ring in lid assembly
Jandy
Pro Series VS FloPro
Variable-Speed Pump
®
When pressure testing the system with water, it is very
important to make sure that the pump basket lid is
completely secure.
1.
2.
3.
4.
5.
Lid with
Locking
Pump
Debris
Basket
(Inside
Pump)
Figure 12. Exploded View of pump
|
Installation & Operation Manual
Warning
Fill the system with water, using care to eliminate
trapped air.
Pressurize the system with water to no more than
35 PSI.
Close the valve to trap pressurized water in the
system.
Observe the system for leaks and/or pressure
decay.
If there are lid leaks, repeat this procedure. For
technical support, call 800.822.7933. In Canada,
call 1-888-647-4004.
Ring
and
Seal
Trap

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido