13. AQUATIMER A3000 open – Variant 2
Connection example for electrical installation
Electric T-junction in the in-wall installation box
Materials required
To be provided by the customer:
• Earth leakage circuit breaker (RCD)
• Conduit for system line
Accessories
A3000 open ECC function controller
with Ethernet connection . . . . . . 4893 00 00
System line
blue, 100 m . . . . . . . . . . . . . . . . 84-032-12.468
blue, 25 m . . . . . . . . . . . . . . . . . 84-032-12.534
gray, not halogen-free, 100 m . . 84-032-12.563
gray, not halogen-free, 25 m . . . 84-032-12.720
Terminating resistor . . . . . . . . . . . 84-100-17.143
Preparing the electrical connection
Position the power supply outside of the wet area, in a separate room, and protect it
with an earth leakage circuit breaker (RCD).
Important!
Only use original lines.
Lay the system line (a) through the conduit, and loop it from the damp-room junction
box to the damp-room junction box.
Let the system line hang out of the in-wall installation box approx. 50 cm.
13.1 Connect the electric T-junction (b).
Order No.
9