Preliminary Checks - BFT SELETTO Instrucciones De Uso

Botonera digital programable
Ocultar thumbs Ver también para SELETTO:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19
EXAMPLE FOR ENTERING A CODE INTO A
COMPASS 485 SYSTEM:
Enter the required code, i.e. 741258.
1) turn ON dip switch n.6 of the COMPASS
485 board.
2) type a 6-figure number of your choice, i.e.
123456 (this becomes the master card +).
3) turn OFF dip switch n.6.
4) type code 123456 (card +) then immedia-
tely afterwards the required code 741258
(within the time allowed by Compass 485
(5s).
5) now just type code 741258 to energise
the opening contact for the COMPASS 485
board. (terminals DOOR 3-4 JP1).
Proceed as described in point 2 for entering
any further code.
For the other functions described in the in-
structions for COMPASS 485, also produce
the MASTER CARD and MASTER CARD
JOLLY, repeating from steps 1-2-3 in the
example, and turning ON dip switches 7 and
8 respectively.
7)SELETTO PUSHBOTTON PANEL IN A SERIAL
SYSTEM (DIP1 OFF)

7.1) Preliminary checks

• The access point to be controlled by means of the
pushbutton panel must necessarily be provided
with a control panel having serial inputs and
outputs.
• Moreover, the control panel must be set to SLAVE,
and have a Zone address other than 0.
• In the case where it is necessary to control more
than one access point by means of the pushbutton
panel, connect the other control units, still set to
SLAVE and still having a Zone address other
than 0, by means of the serial line. Control units
with an identical zone address answer to the
same code.
~
• The 24V
/
power supply can be drawn from
~
outputs "24V
/
ries" on the control panel.
Check maximum absorption of the devices con-
nected.
• The entry of a valid code causes a START
command to be sent along the serial line. Fur-
ther entries of the same code will cause further
START commands to be sent.
The operator will behave differently depending on
the function logic set on the control panel (2/3/4
steps).
• For further information, refer to the specific
instructions for control panel use.
Following the diagram in Fig. 3, proceed to wire
the serial line of the control panels managed by
INSTALLATION MANUAL
– Power supply for accesso-
the SELETTO pushbutton panel, exclusively using
a telephone-type line.
In the case where a telephone cable has several
pairs of wires, it is indispensable to use the wires
from the same pair.
The length of the telephone cable between one
appliance and the next must not exceed 250 m.
7.2)Programming of activation codes (DIP2 OFF)
The Enter function is obtained by simultaneously
pressing key 0 and key 8. Programming can only be
carried out when the pushbutton panel is supplied
with power.
1 Press Enter (0+8) N times, where N represents
the number of figures wanted to make up the
activation code (from 3 to 6 figures).
2 Type the memory location used by the code (from
0 to 15) and press Enter (0+8). A maximum of 16
different codes are therefore possible.
3 Type the number of the serial zone be controlled
with the code (from 1 to 127) and press Enter
(0+8). Do not enter value 0.
4 Enter the activation code, having 3 to 6 figures
(see point 1), and press Enter (0+8).
5 If Enter (0+8) is pressed again within 10s, the
procedure is resumed from point 2 (entering
position⇒zone⇒code).
For example. to attribute code 88776 to position 12,
in order to activate serial zone address 2, proceed
as follows:
1 Press Enter (0+8) 5 times
2 Type 12 (location number) and press Enter (0+8)
3 Type 2 (zone number) and press Enter (0+8)
4 Type 88776 (access code) and press Enter (0+8)
5 To end programming, press any key or wait for
10s.
At the end of programming, reposition DIP2
to ON.
7.3) Making changes to a pushbutton panel
already programmed (DIP2 OFF)
Note: To be able to add codes and/or change pu-
shbutton panel programming, it is indispensable
to know at least one valid code number.
7.3.1) Addition of new codes
1 Press Enter (0+8) 3 times.
2 Type a valid code number entered in the memory
and press Enter (0+8).
3 Type the memory location taken up by the code
to be added (from 0 to 15) and press Enter (0+8).
Using a location already taken up causes the
previous code to be cancelled.
4 Type the number of the serial zone to be con-
trolled with the code (from 1 to 127) and press
Enter (0+8). Do not enter value 0.
5 Enter the activation code, having 3 to 6 figures,
ENGLISH
SELETTO - Ver. 05 - 9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Seletto e

Tabla de contenido