Technical Data

Distance measurement
Inside measurement range
Precision (typical)*
Angle measurement
Measuring range
Resolution
Precision
Laser class
Laser wavelength
Operating temperature
Storage temperature
Automatic switch-off
Power supply
Dimensions (W x H x D)
Weight (incl. batteries)
* measuring distance up to 10 m with strongly reflective target surface
and at room temperature. The measurement deviation may increase by
± 0.2 mm/m for greater distances and under unfavourable measuring
conditions such as strong sunlight or weakly reflective target surfaces.
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must be
collected separately for disposal according to
the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
www.laserliner.com/info

Declaration of conformity

This product conforms to the stipulations of the Directives 2004/108/EC,
2014/30/EU (EMC), 2011/65/EU (RoHS) and 1999/5/EC (R&TTE).
Umarex GmbH & Co KG hereby declares compliance with the funda-
mental requirements and all relevant technical rules and regulations of
the above directives and is therefore authorised to display the CE mark
on the product.
Further information is available at www.laserliner.com or on request.
DistanceMaster Compact Pro
(Subject to technical changes without notice)
0,1 m - 50 m
± 2 mm / 10 m
± 90°
0,1°
0,1°
2 < 1 mW
650 nm
-10°C – 40°C
-20°C – 70°C
30 sec laser / 10 min device
2 x AAA 1.5 Volt batteries
43 x 110 x 27 mm
100 g
17