SmartLine-Laser 360°
Checking the vertical line
Position the device about 5 m from a wall. Fix a plumb bob with a line of 2.5 m length on the wall, making
sure that the bob can swing freely. Switch on the device and align the vertical laser to the plumb line. The
precision is within the specified tolerance if the deviation between the laser line and the plumb line is not
greater than ± 1.5 mm.
Checking the horizontal line
2,5 m
Position the device about 5 m from a wall and switch on the cross laser. Mark
B
C
point B on the wall. Turn the laser cross approx. 2.5 m to the right and mark
point C. Check whether the horizontal line from point C is level with point B
to within ± 3 mm. Repeat the process by turning the laser to the left.
!
Regularly check the calibration before use, after transport and after extended periods of storage.
Guarantee, product care and disposal
This device complies with all necessary standards for the free movement of goods within the EU.
This product is an electric device and must be collected separately for disposal according
to the European Directive on waste electrical and electronic equipment.