Err255:
Received signal too weak or measuring time too long
Err256:
Received signal too strong
Err261:
Outside the measuring range
Err500:
Hardware fault
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents,
scouring agents and solvents. Remove the battery(ies) before storing for
longer periods. Store the device in a clean and dry place.
Calibration
The measuring device should be calibrated and tested on a regular
basis to ensure it is accurate and working properly. We recommend
the measuring device is calibrated every 1 - 2 years. If necessary, contact
your distributor or the UMAREX-LASERLINER service department.
Technical Data
Precision (typical)*
Measurement range (inside) ** 0.2 m - 20 m
Laser class
Laser wavelength
Beam divergence
Operating conditions
Storage conditions
Automatic switch-off
Power supply
Dimensions (W x H x D)
Weight
* measuring distance up to 10 m with strongly reflective target surface
and at room temperature. The measurement deviation may increase by
± 0.2 mm/m for greater distances and under unfavourable measuring
conditions such as strong sunlight or weakly reflective target surfaces.
** at max. 5000 lux
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must be
collected separately for disposal according to
the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=ACX
LaserRange-Master T2
(Subject to technical changes without notice. 19W47)
± 2 mm
2 / < 1 mW (EN 60825-1:2014/AC:2017)
650 nm
< 1.5 mrad
0°C ... 40°C, max. humidity 20 ...
85% rH, no condensation, max. work-
ing altitude 2000 m above sea level
-20°C ... 70°C, max. humidity 80% rH
Dynamic depending on measuring
mode:
Laser: 30 s ... 5 min
Device: 3 min ... 8 min
2 x 1.5V LR03 (AAA)
35 x 100 x 23 mm
82 g (incl. batteries)
11
EN