... the appliance is switched
on but the compressor is
not running ...
... the appliance makes a lot
of noise ...
Technical Information
Technical
information
Whenever the appliance is switched on, the 3-
minute switch-on delay is activated. The
compressor will then start audibly after 3
minutes.
If the dehumidification LED flashes, the
appliance has been set to dehumidification mode
and the ambient temperature is below 18°C. The
compressor therefore switches off (see also
information on "Dehumidification only").
The ambient temperature must be above 18°C
for the appliance to operate in dehumidification
mode.
If "F1" or "F2" is displayed, the temperature
sensors are defective. Call customer service!.
Make sure that the air extraction duct is properly
fitted onto the appliance.
Make sure that the appliance's air inlets and
outlets are free from obstruction.
If the noise sounds like water flowing, then this is
due to the pump which circulates water around
the system so as to enhance the efficiency of the
appliance.
Warning!
Any other kind of fault or repair work must be
dealt with by a specialised technician. Contact
your authorised supplier, the after-sales service
or the Technical Service Network.
Consumption at maximum power................1.180W
Fuse..................................................................10 A
Cooling capacity *........................................2.750W
Operating range
- Temperature control............min. 18°C-max. 35°C
- Dehumidification ................min. 18°C-max. 35°C
* Ashrae 128