... the appliance is switched
on but the compressor is
not running ...
... the appliance makes a lot
of noise ...
Technical Information
Technical
information
Whenever the appliance is switched on, the 3-
minute switch-on delay is activated. T h e
compressor will then start audibly after 3 minutes.
If the dehumidification LED flashes, the appliance
has been set to dehumidification mode and the
ambient temperature is below 18°C. T h e
compressor therefore switches off (see also
information on "Dehumidification only").
The ambient temperature must be above 18°C for
the appliance to operate in dehumidification mode.
If "F1" or "F2" is displayed, the temperature
sensors are defective. Call customer service!.
Make sure that the air extraction duct is properly
fitted onto the appliance.
Make sure that the appliance's air inlets and outlets
are free from obstruction.
If the noise sounds like water flowing, then this is
due to the pump which circulates water around the
system so as to enhance the efficiency of the
appliance.
Warning!
Any other kind of fault or repair work must be
dealt with by a specialised technician. Contact
your authorised supplier, the after-sales service or
the Technical Service Network.
Consumption at maximum power................1.180W
Fuse..................................................................10 A
Cooling capacity *........................................2.600W
Operating range
- Temperature control............min. 18°C-max. 35°C
- Dehumidification ................min. 18°C-max. 35°C
* Ashrae 128
31