G E N E R AL I N F O R M AT I O N S
I N F O R M AT I O N S G E N E R AL E S
F
I N F O R M AC I O N E S D E C AR À C T E R G E N E R AL
E
I n f o r m a t i o n s
I n f o r m a t i o n s
I n f o r m a c i o n e s
D a n g e r o f d a m a g i n g o f a c t u a t o r / w i n d o w
D a n g e r d ' e n d o m m a g e r d u a c t i o n n e u r / f e n e t r e
P e l i g r o d e d a ñ a r d e l a c t u a d o r / s e r r a m i e n t o
GB
• Prior to installation please read carefully these instructions (especially the "Safety Notices").
• Keep these instructions to consult them after installation if necessary.
• Unsuitable application or wrong installation may result in a loss of system operating functions and consequently in damages or/and
injuries.
The actuator is designed for applications on top hinged windows and bottom hinged windows.
• The actuator is for internal use only.
• Only original parts and fittings shall be used to install the actuator.
The working temperature of actuators are: -10° C +60 ° C with maximum relative humidity 60%.
NOTES ON THE ACTUATOR
• Possibility of connection of two or more actuators with synchronization of the speed of the chains.
• Possibility of parallel connection to operate more windows simultaneously.
• Electronic stop in end-stroke positions. Check if the frame is strong enough and if the bracket is firmly fastened (PVC frames).
Protection in case of overload.
WARNING: SAFETY NOTICES
• The actuator is to be mounted only on windows such that the window moving parts and the operator be located more than 8 feet (2.44 m)
above the floor or any other access level.
• Be very careful of moving parts during installation to avoid crushing.
• Bottom hinged windows must be provided with side checks.
• The actuator shall be installed by skilled engineers.
• Prior to installation make sure that:
- the actuator performances comply with the estimated application
- window profiles and fittings are suitable to the stresses caused by the actuator
- window fittings (hinges) and absence of obstacles allow complete opening
- the existing electric systems comply with the regulations in force
- power supply features are those indicated in the actuator specifications
• Interconnection wiring between the parts of the operator shall be in compliance with National Electric Code and relevant local codes,
suitably routed and protected as per the National Electric Code and relevant local codes.
• Before connecting the actuator to power supply make sure it has been turned off to avoid electrocution.
• It's very important to verify that the grounding connection works propely.
• An omnipolar switch shall be provided in the supply mains (according to CEI EN 60335-1).
• Protect the field wiring by routing it in cable ducts .
• In case the actuator is installed on a mobile wing, make sure the supply cable is not subject to stress when operating.
• When assembling and disassembling the actuator, take proper precautions to avoid accidental closing of the window which might cause
injuries to people (impact-squashing-cutting-shearing).
• On windows less high then 1800 mm (C=600), 2400 mm (C=800), 3000 mm (C=1000) use the pivoting brackets.
• By feeding the actuator make sure that operation is regular and that opening and closing limit switches operate correctly.
• When operating the actuator follow the following instructions:
- prevent liquids from entering the actuator
- do not approach moving parts until they have come to a complete stop
- at least once a year check at sight for damages or wear in the supply cable
- to open the window in case of power failure, remove the "split pin + washer" (B).
-
do not carry out any intervention on the actuator, do not remove or disassemble parts of the actuator:
in case of malfunction or damaged cable contact "UCS Ultraflex Control Systems srl".
GUARANTEE
Ultraflex Control Systems S.r.l. products are guaranteed, for a period of two years from the manufacture date, against defects in material
and workmanship.
Alleged defective products returned, freight prepaid, within the above said term, will be repaired or replaced free of charge, at our option, if
found effectively below our quality standards.
This guarantee does not cover other claims for direct or indirect damages.
In particular, we decline liability and exclude guarantee (except for what stated above) if improper installation or misuse should result in a
failure of our products.

CORRECT DISPOSAL OF THIS PRODUCT

The correct disposal of your old appliance will help prevent potential negative consequences for the environment.
Doc. 84407W - Rev. 22/02/11
D a n g e r t o p e r s o n s d u e t o e l e c t r i c i t y
D a n g e r a u x p e r s o n n e s d u e s à l ' é l e c t r i c i t é
P e l i g r o a l a s p e r s o n a s d e b i d o a l a e l e c t r i c i d a d
The following instructions contain important safety information
D a n g e r t o p e r s o n s ( i m p a c t , c r u s h i n g ... )
D a n g e r a u x p e r s o n n e s ( h e u r t , é c r a s e m e n t ... )
P e l i g r o a l a s p e r s o n a s ( g o l p e , a p l a s t a m i e n t o ... )
3 - 7
W a r n i n g
A t t e n t i o n
A t t e n c i o n
Dis. 27948