Outdoor air intake
In the models of the Paris series, it is possible to choose that the entrance of primary air comes from a contiguous place or even from outside
of the house.
In the case of providing air from outside or from a contiguous place, you must purchase the optional kit (KIT-AIR2) for external air intake
(airtight). Simply connect the KIT with a 100 mm diameter pipe to the chosen place. Keep in mind that a too long pipe or with too many
deviations (elbows), far from benefiting the intake of air, causes a great loss of load and, therefore, can cause combustion problems.
Do not forget that this external air intake is independent and different from the input needed for the ventilation unit (turbine), so the decoration
or masonry made to the insert, must have a sufficient air circulation for the flow of the turbine (see drawing D33).
The procedure for placing the optional external air intake kit is as follows:
-
Position the kit below the plane of fire. You must center the kit and position it on the front (inner face) as indicated in the image.
-
With the supplied self-drilling screws, connect the kit to the base of the appliance.
-
Connect the air intake to the exterior or selected environment through a 100 mm diameter pipe.
2.2.8
OPERATION: FUEL RECHARGEING ON PARIS 70V-G AND PARIS 90V-G
MODELS
In the Paris 70V-G and Paris 90V-G models, the door can be raised, thanks to a system of
counterweights and pulleys, the door can be easily opened. Two handles are integrated in
the door to facilitate its lifting. Do not forget to use the supplied glove or the "cold hands"
accessory provided in the accessory box to manipulate the door opening when the appliance
is hot and there is a risk of burns.
Also, at the top of the door is a safety system that must remain open to allow the door to be
raised and lowered.
ATTENTION!!!! The appliance will be received with the system closed to prevent the door from
being lifted during transport. Don't forget to open the handle so that you can lift the door.
For refuelling, the use of the lifting door is recommended to facilitate operation.
NOTE: It is MANDATORY to disconnect the operation of the turbine (position 0) when the lift
door of the insert is opened, since depending on the smoke installation it is possible that small
turbulences are created in the combustion chamber, causing the exit of smoke and/or ashes to the
room where the device is installed.
2.2.9
CLEANING AND/OR REPLACEMENT OF THE GLASS IN MODELS PARIS 70V-G
AND PARIS 90V-G
In order to facilitate the cleaning and/or replacement of the glass, the option of lifting the door is
ruled out; the door must be opened in a folding manner (from right to left). In this case, the safety
handle should be closed to prevent accidental lifting of the door and the door should be opened using the handle on the accessory box. After
cleaning and/or replacing the glass, you must close the door again and open the safety handle to use the lifting door.
IMPORTANT: The cleaning of the glass must be carried out with the device cold. Special care should be taken when opening the door to
ensure that the door handle is closed and that there is no accidental lifting of the door that could cause the glass to break.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
34
D33
D35
D32
D34
INSERTS