Bosch GRL2000-40H Instrucciones De Funcionamiento página 16

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Manual Operation and
Manual Slope
The automatic leveling of the laser level can be
switched off (manual operation):
– in the horizontal position for both axes inde-
pendently of each other
– in the vertical position for the X-axis (the
Y-axis cannot be leveled in the vertical posi-
tion) (GRL2000-40HV only).
The X-axis and Y-axis are marked on top of the
GRL.
+ Y
- X
It is possible to set up the laser level at any
inclination in the manual operation mode. The
axes can also be tilted additionally, within a
range of ±8% on the laser level.
To switch off the automatic leveling for the X-
axis press the button for dual-axis slope opera-
tion 2 once. The X leveling indicator LED 5 will
start flashing red. During this time, the X-axis
can be tilted additionally by pressing the lower/
upper direction buttons 4 and 12.
- X
5 seconds after the last adjustment the X lev-
eling indicator LED 5 will light up red continu-
ously.
To switch off the automatic leveling for the Y-
axis (while the X-axis is leveled) press tthe but-
ton for dual-axis slope operation 2 twice. The
Y leveling indicator LED will start flashing red.
During this time the Y-axis can be tilted addi-
tionally by pressing the lower/upper direction
button 4 and 12.
2610055315 GRL2000-40 02-20.indd 16
+ Y
5 seconds after the last adjustment the Y lev-
eling indicator LED 5 will light up red continu-
ously.
To switch off the automatic leveling and/or tilt
+ X
both X and Y axis, first tilt the Y-axis as de-
scribed above and then the X-axis by pressing
the button for dual-axis slope operation 2 again
and adjusting it accordingly.
- Y
Single Slope
5 seconds after the last adjustment both X and
Y leveling indicator LEDs 5 will light up red con-
tinuously.
If one of both axes is in manual operation (re-
spective leveling indicator LED is continuously
red) press the button for dual-axis slope opera-
tion 2 to additionally tilt the axis, which was last
+ X
set to manual operation. Press the button for
dual-axis slope operation 2 again to adjust/tilt
the other axis.
To reset both axes to automatic leveling press
the button for dual-axis slope operation 2 as
many times as necessary - until both X and Y
leveling indicator LEDs 5 start flashing green
(leveling still in process) or light up green.
Manual Operation and Manual
In vertical mode only the X-axis will be reset
to automatic leveling (the Y-axis cannot be lev-
eled in the vertical position).
The Y leveling indicator LED 5 is off by default,
unless it has been tilted/moved from its default
position.
-16-
Slope in Vertical Mode
(GRL2000-40HV only)
- Y
Dual Slope
3/2/20 7:07 AM

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Grl2000-40hvRc4

Tabla de contenido