Cleaning and Maintenance

Pressure release valve
The safety valve is designed to release any excess pressure and to let you release the pressure after
spraying.
Do not interfere with the setting of the air pressure safety valve.
Plunger head
The O-Ring should be kept lubricated to slide freely in the barrel and so pump air efficiently.
To apply grease proceeds as follows.
Remove the pumps assembly by unscrewing in an anti-clockwise direction.
Locate the pump handle into the carrying position and grip the barrel.
Unscrew the plunger retaining cap from the pump barrel by rotating the handle.
Withdraw the plunger and apply silicone grease to the O-Ring.
When re-assembling ensure the O-Ring is not trapped between the outer edge of the plunger moulding and
the inside of the pump barrel.
Pump non-return valve:
(Situated at the bottom of the pump barrel)
This stops the compressed air in the container from escaping back into the pump.
If it is faulty, the unlocked pump handle will rise when the container is pressurized.
To remove the valve, lift the edge of the valve and pull. (take care not to damage the sealing face of the
barrel).
To replace place the valve over the centre hole and push down firmly.
Pump barrel sealing rings
These make an air tight seal between both the pump barrel and adapter.
Also between the adapter and container when both are screwed down tight.
To check this, turn the pressurized sprayer upside down and if there is a leak, liquid will be forced from the
joints.
Nozzle cap
Keep this clean and free from obstruction.
Also, the two swirl grooves at the end of the lance must be kept clean and free from sediment to ensure a
good spray pattern.
The nozzle O-Ring should be kept lubricated with silicone grease.
Lance
Keep the trigger clean and free from sediment and chemicals by regularly flushing through after use.
If necessary remove and clean the shuttle in the trigger.
Outlet and dip tube
To rewash the outlet or replace the dip tube, unscrew the hose nut and pull the outlet spigot and dip tube
through the outlet body.
Winter use
Drain liquid from all parts after use to prevent damage from freezing.
Annual Maintenance
At least once a year thoroughly clean the whole sprayer and apply silicone grease to all moving parts.
Test with water and if any washer or seal has perished it must be replaced
6.2
Troubleshooting
Fault
Weak or no spray
Distorted spray
Leaks
V. 03 – 10/11/2015
DT20050
May be due to
1.insufficient pressure or loss air.
2.obstruction
Partial blockage in spindle or nozzle
1.build up of sediment or foreign
4
Remedy
1.if insufficient pressure check
maintenance
2.if obstruction check
maintenance
Check maintenance
1.check maintenance and if
©Velleman nv