5.
Variants of the power supply
a. Direct wiring (230V/50Hz AC)
• The electrically operated leg rest is connected via a transformer/control unit with a power cable
supplied by the customer.
• Connection to the power supply must be made only by a qualified electrician.
b. Power supply (230V/50Hz AC)
• The electrically operated leg rest is plugged into a cover protected socket supplied by the
customer via a transformer/control unit with an external power cable.
• Optional: Cable conduit for floor anchoring (fig. 9) to reduce risk of tripping. Lay the power
supply cable from the wash unit through the conduit to the socket.
• If the wash unit is wall mounted (input and output water via installation shaft from the wall), the
power supply cable can be laid to the wall in the upper area of the installation shaft and be
plugged into a wall socket there.
• When several units are installed in-line the power supply cable of one unit must not be connected
further to another unit.
Environment:
For the correct disposal of this product, special national regulations or ordinances may apply. Please observe
these regulations carefully.
Voltage:
Europe
Device in protective class:
EU conformity:
Certification:
GB
230 V / 50 Hz, 15 W
1I
The washing unit complies with the regulations as under the low-voltage
regulations 98/79/EG and the regulations governing electromagnetic
compatibility 89/336/EWG.