Test Procedure - SATA air check set Instrucciones De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
Operating instructions SATA air check set
Description
Max. inlet pressure
Recommended test pressure
Max. test pressure
Air consumption
Test duration
Max. ambient temperature
Weight

8. Test procedure

Warning!
Risk of injury from bursting compressed air hose
If an unsuitable compressed air hose is use, it can be damaged by too
much pressure and explode.
→ Only use solvent-resistant, antistatic and technically flawless hose
for compressed air with permanent pressure resistance of min. 10 bar,
bleeder resistance of < 1 MOhm and min. inner diameter of 9 mm
(# 53090).
Attention!
Distorted results caused by damaged test membrane
If the test pressure is too high, this can damage the test membrane and
distort the results.
→ Comply with the max. tolerable test pressure (see chapter 7).
Note!
To avoid distorted results, always work with great care and cleanliness
when inserting the test membrane and during the test procedure. Always
use the supplied tweezers to insert the test membrane.
10.0 bar
0.8 bar
1.6 bar
150 Nl/min at 0.8 bar
10 min.
EN
50 °C
490 g