Problem
The Pilot light flashes.
The Alarm light flashes.
The compressor operates con-
tinually.
The temperature in the freezer is
too low.
The temperature in the freezer is
too high.
There is too much frost.
Closing the door
1. Clean the door gaskets.
2. If necessary, adjust the door. Refer to "Installation".
Possible cause
The mains plug is not connected to
the mains socket correctly.
The appliance has no power. There is
no voltage in the mains socket.
The appliance is not working properly. Contact a qualified electrician.
The temperature in the freezer is too
high.
The temperature is not set correctly.
The door is not closed correctly.
The door has been opened too fre-
quently.
The product temperature is too high.
The room temperature is too high.
The Fast Freeze function is switched
on.
The temperature regulator is not set
correctly.
TheFast Freeze function is switched
on.
The temperature regulator is not set
correctly.
The door is not closed correctly.
The product temperature is too high.
Many products are stored at the
same time.
Products are too near to each other.
Food is not wrapped correctly.
The door is not closed correctly.
The temperature regulator is not set
correctly.
Connect the mains plug to the mains
socket correctly.
Connect a different electrical appliance
to the mains socket.
Contact a qualified electrician.
Refer to "Excessive Temperature Alarm"
Set a higher temperature.
Refer to "Closing the door".
Do not keep the door open longer than
necessary.
Let the product temperature decrease
to room temperature before storage.
Decrease the room temperature.
Refer to "Fast Freeze function".
Set a higher temperature.
Refer to" Fast Freeze function".
Set a lower temperature.
Refer to "Closing the door".
Let the product temperature decrease
to room temperature before storage.
Store less products at the same time.
Store products so that there is cold air
circulation.
Wrap the food correctly.
Refer to "Closing the door".
Set a higher temperature.
3. If necessary, replace the defective door gaskets. Con-
tact the Service Center.
Solution