Protection and Safety
Description
Insulation
Insulation
Insulation
Leakage current
Input fuse
Output fuse
Minimum output voltage of operation
(Battery Detector)
Reverse output polarity
Thermal protection of semiconductors
(Temperature of Thermal Alarm)
Safety Requirements (Rules)
EMC Requirements (Rules)
D01001-02
Battery charger BC1
Symbol
Test Condition
-
Mains to Battery side
-
Mains side to Earth
-
Battery side to Earth
I
Supplied equipment
L
F1
Inside the equipment
F2
Inside the equipment
-
Equipment turn on
-
At the connection to the
Battery
-
Ta=55°C
-
EN60335-1, EN60335-2-29
-
EN55014-1, EN61000-3-3
EN55014-2, EN61000-4-2
EN61000-4-4, EN61000-4-5
EN61000-4-6, EN61000-4-11
English
Value and/or
Unit
Range
1250
V
AC
500
V
DC
500
V
DC
< 3
mA
10 (delayed)
A
40
A
1,3
V/cell
Protection
-
provided by
fuse F2
100
°C
-
-
-
-
15