5.
ASSEMBLY INSTRUCTIONS
Required components for installing an Alufix on concrete. The fixings required for installation are not included
with the product and the following components will also be required:
5.1 SKYLOTEC ALUFIX AP-003 anchor point, installed, with Würth
Screw Anchor W-SA A4 12x100
Required fixings:
The Alufix anchor point is approved according to EN 795:2012 and CEN/TS16415:2013 N
device for 3 people and according to ANSI Z359.1:2007 N
anchoring uses fasteners (screws) approved by technical building regulations.
The length should be selected according to the thickness of the substructure plus the maximum height of the Alufix.
Hammer drill
Concrete drill (pay attention to the installation instructions for the fixings)
Blow-out pumps for cleaning the drill holes (Würth item no. 0903 990 001)
Cleaning brushes (Würth item no. 0905 499 007)
Calibrated torque wrench
Ratchet key and SW 18 plugs
The area in which the anchor point is to be installed must be able to safely take static forces of 14kN for EN 795:2012 and
44.4kN for ANSI Z359.1:2007. This area must therefore be statically approved accordingly.
Number of users EN 795.2012 CEN/TS16415:2013:
Number of users ANSI Z359.1:2007:
All directions
All dimensions in mm.
MAT-MA-0038-EN ALUFIX
[kN] = 44.4 kN for attachment if it can be proven that the
R,d
04/07/2017
[kN] = 14 kN as an anchor
R,d
Page 4 of 12