PROBLEM
LACK OF STEAM
DISTRIBUTION FROM
THE PIPE
LEAKAGE FROM THE
FILTER HOLDER
DIFFICULT
POSITIONING OF THE
FILTER HOLDER ON
THE COUPLING RING
INCORRECT
POSITIONING OF THE
FILTER HOLDER AFTER
PLACING IT ONTO THE
GROUP
36
7 TROUBLE SHOOTING
DIAGNOSTICS/SOLUTION
The steam pipe nozzle is
obstructed, clear it by
using a pin. This problem
depends on the
introduction of the spout
into the milk.
Possible causes:
1-The lower bowl gasket
is worn or encrusted.
2-The filter holder is
positioned incorrectly on
the group.
3-The filter into the filter
holder is damaged.
The filter holder can not
be positioned.
The filter holder handle,
after fixing it to the group,
is turned to the right more
than usual. The lower
bowl gasket is worn.
cod.9941038
English
ed.02/04
rev.00
SUGGESTIONS
Clean the steam spout
after using it.
In all above-mentioned
cases, call a skilled
technician.
The problem depends on
the excessive coffee dose
inside the filter holder.
Contact a skilled
technician to replace the
lower bowl gasket.