Working Display; 4.3 Status Display And Explanation; Setting The Charging/Discharging Parameters - ROBBE 8194 Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

- The 'Set' key can call up the following languages one after
the other.
- Deutsch (German)
- Französisch (French)
- Spanisch (Spanish)
- Italienisch (Italian)
- Englisch (English)
- Select the desired language and press the 'DISPLAY' key.
This will display the "working" display of the first charge Out-
put.
4.2

WORKING DISPLAY

The display will make all necessary information available to the
user during a discharging or charging procedure.
Example of a "working" display
Status
Output num-
display
ber
Time elapsed in min.
and sec.

4.3 STATUS DISPLAY AND EXPLANATION

N
No battery
C
Charge
D
Discharge
D/C
Discharge/Charge
F
Finish
Ready
R
-
Negative value
+
Positive value
4.4
SETTING THE CHARGE/DISCHARGE PARAME
TERS
To set the parameters for a new procedure, press the SELECT
key.
- The display changes to the "setting" display
- Select a charge Output (1...4) with the SET key.
- Navigate through the "setting" display by repeatedly pres-
sing the SELECT key. A cursor marks the adjustable value.
- The values are changed by pressing the SET key.
Profi-Home-Charger
Actual
Charge or
voltage
discharge current
Charged or discharged
capacity
No battery connected
Charging procedure
Discharging procedure
Discharge/charge cycle
Process completed
Charger ready
Discharge value (current or capacity)
Charge value (current or capacity)
Example for the "setting" display of charge Output 2
Output num-
Charge current
ber
(CHARGE)
Cursor
Operating
Battery
mode
type
Explanation:
The individual parameters can be set in the following ranges or
limits:
Output number:
CH:
Battery voltage
0 - 8 V:
8 -10 V:
10 -13 V:
13 -20 V:
over 20 V:
DC:
Battery voltage
0 - 6 V:
6 - 8 V:
8 -10 V:
10 -16 V:
over 16 V:
Charge and discharge currents are dependent on the battery
voltage and are automatically limited to the preceding
values by the device.
Operating modes: (Programs)
- CHA: Charging in automatic mode
- CHM: Charging in manual mode
- DCA: Discharge-charge in automatic mode
- DCM: Discharge-charge in manual mode
- REA: 3 cycles discharge-charge in automatic mode
- REM: 3 cycles discharge-charge in manual mode
- D/C: Regeneration program, with discharging and subse-
quent C/5-charging
Battery types:
NC:
Nickel cadmium batteries (NC)
NH:
Nickel metal hydride batteries (NiMH)
Pb:
Lead batteries
LI:
Lithium-ion batteries (Li) 3.6V/cells
LP:
Lithium-ion polymer batteries (Lp) 3.7V/cells
C
Cell count
NC batteries:
1 to 16 cells (nominal voltage 1.2...19.2V)
NH batteries:
1 to 16 cells (nominal voltage 1.2...19.2V)
Pb batteries:
1 to 6 cells (nominal voltage 2...12V)
LI batteries:
1 to 4 cells (nominal voltage 3.6...14.4V)
LP batteries:
1 to 4 cells (nominal voltage 3.7...14.8V)
Ah:
Battery capacity
0.1 to 20 Ah with different increments:
0.1...1.0 Ah
= increment 0.1 Ah
1.0...5.0 Ah
= increment 0.5 Ah
6.0...20 Ah
= increment 1.0 A
With intermediate values, set the next higher value.
19
Order No.
8194
Discharge current
(DISCHARGE)
Cell count
Nominal capacity
1 to 4
Charge current
0.1...5 A
0.1...4 A
0.1...3 A
0.1...2 A
0.1...1 A
Discharge current
0.1...5 A
0.1...4 A
0.1...3 A
0.1...2 A
0.1...1 A