3.5 Electrical connection

1.
An electrical supply should be available within the reach of the included power cord.
Do not use extensions to connect the machine's power cord to the electrical supply.
2.
Before making the electrical connections, read the specifications on the rating plate
to ensure that they comply with those of the electrical supply. Electrical connection
should be made by a qualified service technician who will observe all applicable
safety codes and the national electrical codes.
3.
Check the correct connection (rotation) of the machine. If connected wrong, the
motor will run, but the knives and pressing plate will not move. If necessary, you will
have to exchange the position of 2 phase wires.
When connecting this machine to the mains supply, ensure that the following is carried out:
1.
An isolating switch is fitted within 2m of the machine.
2.
A grommet/gland is fitted around the power supply cord entry hole into the machine.
3.
All wiring connections must be checked and tight.
Once the electrical connection has been made, the machine is ready for use.
ELECTRICAL SUPPLY REQUIREMENTS 380VAC, 50Hz, 3PH+E
4. MOUNTING GRIDFRAME
In order to mount the gridframe you will need the following parts:
1
Two long screws
1
1
1
6
2
One cover
2
2
2
Step 1:
Remove springs from
axes.
Step 2:
Loosen the two socket
heads on both sides
SINMAG EUROPE BVBA