Cell
Insert the cell in the cell housing making sure that its open side window is
pointing to the side water inlet. Make sure the O ring is fitted correctly and
tighten the thread. Then, connect the cell cable connector to the cell terminals. Verify
that the connector is orientated so that its small hole is aligned with the thin pin on
the cell before trying to plug the connector.
NOTA: The cell pins should only be tighten slightly and always by hand.
Never use a tool because the cell could be damaged. Water tightness is
assured by the internal seal.

4. WATER PREPARATION

Use preferably water from the metropolitan network. If water from a different origin
is used, have it analyzed and verify so that there is no contraindication regarding
salt electrolysis (such as a high concentration of metals or calcium, for example).
Make also sure the water complies with health standards.
Balance the water before starting your chlorinator and add the amount of chlorine
stabilizer prescribed by the manufacturer (normally 1 kg per 25m
exceed the dose because this will block the disinfection action of the chlorine.
NOTE : Stabilizer prevents the disintegration of chlorine due to UV radiation. The
lack of stabilizer could make it difficult to reach a chlorine residual concentration
during high sunshine periods and will oblige you to produce more chlorine reducing
the life span of your cell. In general, and specially if you don't use stabilizer, we
recommend to chlorine during low sunshine hours.