6. Operating Mode:
- TX: The mode where the relay sends commands to other devices depending on the
confi gured command (in this mode, the relay does not activate the output).
- RX: The mode where the relay activates the output if the confi gured command is received
by the bus and coincides with the other confi gured parameters.
7. PRG: Programming Access button.
8. Min all / sec single: Buttons for Functions and Activation Times
- For Functions: In combination with the PRG button (programming input), they are
pressed to program the relay's different possible functions.
- For activation times.
* Timed: This allows you to confi gure the activation time between 1 and 120 seconds
in the seconds range and between 1 and 120 minutes in the minute rage.
* Continued: Allows the relay to be confi gured to keep the contact closed until
deactivation occurs by means of a short-circuit between the RESET and -.
9. C, D, T: LED diodes that give information when programming, relative to the status: off,
on, fast fl ash...etc.
10. Telephone Connector: For the DUOX Programmer connection.
1.1 AVAILABLE FUNCTIONS/ CONFIGURATIONS
The functions available on the relay are summarised below. This manual describes the most
common uses.
In the DUOX Relay Advanced Manual cod. 97822 at www.fermax.com you can fi nd all of
them, including confi guration from a Duox Programmer.
Available functions in TX Mode:
- Lock-release function after receiving a call.
- Lock-release function to a confi gured panel.
- Guard-unit call function.
- F1 relay activation or deactivation function.
- F2 relay activation or deactivation function.
- Remote relay activation or deactivation function.
- Doormatic function.
Available functions in RX Mode:
- Activating the relay upon receiving a lock-release command.
- Activation upon receiving a guard-unit call command.
- Activation upon receiving a call to residence command from a panel.
- Activation upon receiving an Auto-on command.
- Activation upon receiving an Activate F1 relay command.
- Activation upon receiving an Activate F2 relay command.
- Activation upon receiving an Activate/Deactivate relay command.
- Activation of the relay for an indefi nite time.
Note:
- Whenever terminals from different blocks are required to activate the same relay, it must be
confi gured as General Entrance.
Other confi gurations:
- Confi guration of activation times via integrated push-buttons.
- Resetting Parameters.
Page 5