2. CONFIGURATIONS - FUNCTIONS
CONFIGURATIONS
The DUOX relay can be confi gured as Block (2.1) or as General Input (2.2).
2.1 CONFIGURATION AS BLOCK
Connect the DUOX relay, press the "PRG" pushbutton, and the C led should light up. You
will then have 60 seconds to program its address. To program the address, make a call
from one of the terminals that is connected to the BUS OUTPUT terminal. The outdoor
panel of the block must previously have been programmed with the parameters of the
block number.
In this way, the block number will be confi gured in the relay. The relay can then be activ-
ated from any of the terminals that belong to this block number.
2.2 CONFIGURATION AS GENERAL ENTRANCE
If the relay is in RX mode and F1 or F2 command programming, it can be confi gured as a
general entrance block.
To do this, repeat the steps mentioned in 2.1, but make sure that a bridge has been set up
in advance between the – terminals and RESET/DISABLE.
In this way, the block will be confi gured as general entrance, and this relay will be able to
be activated from any monitor or guard unit, regardless of the block number.

2.3 RESETTING PARAMETERS

Function description.
It performs a reset of the parameters to the default values:
- Confi gured command: None
- Relay address: 000
- Relay block: 00
- Continued mode: Deactivated
- Panels: Not confi gured
- Terminals: Not confi gured.
- Start of the Range: Not confi gured.
- End of the Range: Not confi gured.
- List of terminals: Empty.
- Activation time: 3 seconds.
Function confi guration.
1.
Press the PRG button 4 times so that the C, D and T leds remain blinking rapidly.
2.
Press the Min/All and Sec/Single buttons simultaneously, the LEDS remain fi xed for
4 seconds so that when they are off, the relay´s confi guration is reset to the default
parameters.
Notice:
- If the duox relay has been previously confi gured, and if you are unsure about the previous
confi guration, we recommend performing a parameter rest to not interfere with the prior
confi gurations.