Storing The Tool; Instructions For Periodic Maintenance - Makita XBU02 Manual De Instrucciones

Ocultar thumbs Ver también para XBU02:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2
1
1. Locking ring 2. Sprocket

Instructions for periodic maintenance

is performed regularly and properly. Failure to perform the prescribed maintenance work can lead to
Check item / Operating
time
Chain saw Inspection.
Cleaning.
Check at
service
center.
Saw chain Inspection.
Sharpening
if necessary.
Guide bar
Inspection.
Remove
from the
chain saw.
Chain
Check the
brake
function.
Have it
inspected
regularly at
service
center.
Chain
Check the
lubrication
oil feed rate.
Switch
Inspection.
trigger
Lock-off lever Inspection.
Before
Everyday
operation
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTICE: Make sure that the sprocket is

Storing the tool

1.
Clean the tool before storing. Remove any
chips and sawdust from the tool after removing
the sprocket cover.
2.
After cleaning the tool, run it under no load
to lubricate the saw chain and guide bar.
3.
Cover the guide bar with the guide bar
cover.
4.
Empty the oil tank.
Every
Every 3
week
month
-
-
-
-
-
-
-
-
-
-
-
-
21