Troubleshooting

Fault: Motor does not start
Cause
Remedy
Mains circuit-
Check and reset
breaker has been
mains circuit
tripped
breaker
Overload protection
Let vacuum
has been tripped
cleaner cool for
approx. 5 minutes
Fault: Poor suction performance
Cause
Remedy
Filter bag is full
See "Emptying the
container"
Suction hose / tool
Clean suction
is clogged
hose / tool
Filter element is
See "Cleaning the
fouled
filter element" and
"Replacing the fil-
ter element"
Gasket between
Clean or replace
upper part of vac-
gasket
uum cleaner and
container is fouled
or faulty
SE 122
Fault: No suction performance when
wet-vacuuming
Cause
Remedy
Container full
See "Emptying the
(intake port is
container"
sealed by float)