User's Guide
Then display shows "beep x", this used to set the check weighing type, use Tare key to select the check weighing mode, press
key to sure.
Beep 1: beeper will on when weight between hi limit and low limit range.
Beep 2: beeper will on when weight out of hi limit and low limit rang.
Beep 0: beeper will not on whether.
If the printer has been set as "EPM", you could set the year/date and time, the format is YYYY/MM/DD HH:MM.
Example: 2008/12/01 15:32.
Then display show the power auto off time , you can use Tare key to select the time.
0: shut off power auto off function.
3: the scale will auto power off after 3 minutes if the weight without any change or no key is pressed.
5: the scale will auto power off after 5 minutes if the weight without any change or no key is pressed.
15: the scale will auto power off after 15 minutes if the weight without any change or no key is pressed.
30: the scale will auto power off after 30 minutes if the weight without any change or no key is pressed.
Then display show return. Press the
10. ADULT OPERATE
LINEAR CALIBRATE
To start calibration turn the scale off and then turn it back on. Press the
9 to 0 on the display.
The display will show "unLoAd". Remove all weight from the pan and then press the
The display will then show the first calibration weight request. Put this weight on the platform and then press the
The scale should be stable before pressing the
stable.
After all calibrate weight completed, press
The scale will begin counting back to zero after the last weight has been selected.
Calibration weights
MODEL
Weight 1
Weight 2
Weight 3
NORMAL CALIBRATE
To start calibration turn the scale off and then turn it back on. Press the
9 to 0 on the display.
The display will show "unLoAd". Remove all weight from the pan and then press the
Then use
,
after stable indicator on, press
After selfchecking again, RAD is ready for you.
CHECK INTERNAL COUNTS
To view the A/D count press the
Press
to return to normal.
CAPACITY SETTING
To set the capacity press the
Press
key to select the capacity and press the
28
key to come back to the normal weighing mode.
to complete the calibration.
RAD6
zero
2 kg
6 kg
y
key to key in calibrate weight, press
key to sure.
key and the
key and the
Top loading scale
and
key to accept a weight. The stability indicator will turn on to show the value is
RAD series
RAD15
zero
5 kg
15 kg
and
key to sure, display shows "load", put this weight on platter,
key at the same time while the scale is performing the initial check at power-on.
key at the same time while the scale is performing the initial check at power-on.
key to make sure.
keys together during the initial counting from
key to set the initial zero point.
key when stable.
RAD30
zero
10 kg
30 kg
keys together during the initial counting from
key to set the initial zero point.
Model RAD