7-day - each day can be programmed with different times and
temperatures.
5/2 day - one set of times & temperatures for weekdays, and another
set for weekends.
Optimum start control - function which switches the heating on
earlier than the Event 1 programmed time to ensure the required
temperature is achieved by the set time.
Chrono-proportional control - energy saving feature which fires the
boiler at regular intervals to maintain a set temperature, achieving a
constant ambient environment for the user.
Setting Optimum Start Control
Set Sw2 to OSC ON
(see DIL settings page 4)
Select OPTIMISER CURVE in
programming mode
A Event 1 Set Point
B Deviation from Set Point
C Switch On Time prior to Event
D Optimiser Curve Setting
TP7000 Wiring (not RF models)
2
1
COM
ON
M 24V models only
B
C
24V
ELECTRONICS
3
4
5
OFF
M 230V models only
L
N
230V
A
-1˚C
D
B
-2˚C
-3˚C
-4˚C
120
90
min.
min.
6
7
REMOTE
SENSOR
'A' models
only
30
60
Event
min.
min.
time (0)
C
GB
5