INSTALLATION INSTRUCTIONS
WARNING
Check all gas supply fittings for leaks before each use. DO NOT use the grill until all connections
have been checked and do not leak. DO NOT smoke while leak testing. NEVER leak test with an
open flame. Make a solution of one part liquid detergent and one part water. You will need a spray
bottle, brush, or rag to apply the solution to the fittings. For the initial leak test, make sure the liquid
propane cylinder is full.
TO TEST
1. Turn the burner valves off.
2. Turn the liquid propane cylinder valve counterclockwise to open the valve.
3. Apply the soap solution to all gas fittings. Soap bubbles will appear where a leak is present.
4. If a leak is present, immediately turn the gas supply "OFF" and tighten leaky fittings.
5. Turn the gas back "ON" and recheck.
6. S hould the gas continue to leak from any of the fittings, turn the gas supply "OFF" and contact
customer service at 1-800-963-0211.
7. If there is evidence of excessive abrasion or wear, or the hose is cut, it must be replaced prior to
the outdoor cooking gas appliance being put into operation.
• O nly those parts recommended by the manufacturer should be used on the grill. Substitutions will
void the warranty.
WARNING
DO NOT store grill indoors unless the cylinder is disconnected. DO NOT store cylinder in a building,
garage, or any other enclosed area, and keep out of reach of children at all times.
INSTALLER FINAL CHECK
Maintain specified clearance of 24 inches from combustible materials and construction.
• All internal packaging has been removed.
• The hose and regulator are properly connected to the liquid propane cylinder.
• The unit has been tested and is free of leaks.
• The gas supply shutoff valve has been located.
• All burners are installed.
• Keep the instruction manual for future reference.
WARNING
• T he grill and its individual shutoff valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressure in excess of 1/2-in. PSI (3.5 kpa).
• T he outdoor cooking gas appliance must be isolated from the gas supply piping system by closing
its individual manual shutoff valve during any pressure testing of the gas supply piping system at
test pressure equal to or less than 1/2-in. PSI (3.5 kpa).
• D O NOT store spare liquid propane cylinders under or near this appliance to avoid the risk of fire
which could cause death or serious injury.
• N EVER fill the cylinder beyond 80 percent capacity. Failure to do so could result in a fire causing
death or serious injury.
12
Lowes.com/masterforge