• Process
Use knob B to choose or confi rm a welding mode by select-
ing and pressing Short or Pulsed for at least 2 seconds.
Short
indicates that the short synergic welding mode is
selected.
Pulsed indicates that the pulsed synergic welding mode
is selected.
• Welding mode (Start Mode).
Mode 2T, the machine starts welding when the torch
button is pressed and stops when this is released.
Mode 4T, to start welding, press and release the torch
button. To complete welding, press and release again.
To choose the welding start mode 2T or 4T, select one
of the 2 modes by means of the knob B and press the
knob B for less than 2 seconds to confi rm the choice.
This operation always returns us to the previous display
page (PROCESS PARAMS).
• Spot and pause time (Spot).
If we select the spot ON time, the Spot Time function
appears on the display screen. If we select this, we
can adjust it from 0.3 to 25 seconds by means of
the adjustment bar. Besides this function, the display
screen also shows Pause Time. If we select this, by
means of the adjustment bar, we can regulate the
pause time between one welding point or section and
another. The pause time varies between 0 (OFF) and 5
seconds.
To access the Spot Time and Pause Time functions,
press the knob B for less than 2 seconds. Adjustment
is always made by means of the knob B. To confi rm,
simply press it for less than 2 seconds. Once the
choice has been confi rmed, return is always made to
the display page (PROCESS PARAMS).
• Inductance
Adjustment can vary from -9.9 to +9.9. Factory setting
is zero. If the fi gure is negative, the impedance drops
and the arc becomes harder, while if it increases, the
arc is softer.
To access this function, simply highlight it using the
knob B and press it for less than 2 seconds. The display
screen A shows the adjustment bar. The fi gure can be
changed and confi rmed by pressing the knob B for less
than 2 seconds.
• PP Force.
Adjustment can vary from -99 to +99.
By using Push-Pull torch function PPF (Push Pull For-
ce) is enabled which adjusts the drive torque of the
push-pull motor in order to make the wire feed linear. If
the set value is modifi ed, the display shows the letters
PPF beside the new value.
To access this function, simply highlight it using the
knob B and press it for less than 2 seconds. The display
screen A shows the adjustment bar. The fi gure can be
changed and confi rmed by pressing the knob B for less
than 2 seconds.
• AUTO burnback
The adjustment can vary from -9.9 to +9.9. Its purpose
is to adjust the length of the wire coming out of the gas
nozzle after welding. A positive fi gure corresponds to
greater wire burning.
Default is Auto.
To access this function, simply highlight it using the
knob B and press it for less than 2 seconds. The display
screen A shows the adjustment bar. The fi gure can be
changed and confi rmed by pressing the knob B for less
than 2 seconds.