3
Description
3.1
Technical data
Table 3-1: Technical data
Dimensions
Capacity
Weight:
•
Standard 4 m
Material recycling
Noise level
Max. temperature, extracted air
Max. vacuum
4
Mounting instruction
See Figures 2–8. Ensure that the surface, on which to mount the arm is level
and use the wall bracket to mark the holes. Use vibration secured fixing bolts
and nuts suitable for the wall material. The bolts much each stand a torque
force of minimum 1700 N (380 lbs).
5
Adjusting the links
See Figure 9. The links are factory set for normal working position. Always
check and adjust the links so they will suit the users preference. See Figure 10
for correct positioning.
WARNING!
Risk of personal injury.
The arm must not be used in environments where static electricity could cause
explosion.
6
Maintenance
Maintenance is recommended at least once a year.
•
Check that the hose is intact. Clean the hose if it is dirty. If necessary
change the hose.
•
Adjust the links, see Figure 9.
•
Tighten all the arm profile fixing bolts.
•
Check the mounting of the arm on wall.
•
Check the airflow. If it is too low, the ventilation system must be
inspected.
6.1
Spare parts
Installation, repair and maintenance work is to be carried out by qualified
personnel using only original Nederman spare parts. Contact your nearest
authorized distributor or Nederman for advice on technical service.
Extraction Arm Standard 4 m
See Figure 1.
600–900 m
/h
3
16.5 kg
91 weight-%
68 dB(A) ISO 11201
70 °C
1500 Pa
EN
13