Troubleshooting
8.2 Error messages
Display
Possible cause
The ferrule was not well processed and blocks the
mechanics.
v
v
Triggering mechanism actuated too briefly. The
machine does not start
v
v
Triggering mechanism actuated but wire was re-
moved too quickly
v
v
Front flap is open.
v
v
Stop switch fault.
– Stop switch does not stop.
v
v
– Stop switch is not pressed.
Start switch fault
– Start switch not free.
v
v
The wire was inserted too early
Motor fault
– Motor not running or motor jammed
v
v
– Filling level monitoring S1 addressed too
briefly.
Servicing message
– Piece quantity for servicing reached.
v
Drum position incorrect.
v
Setting faults
– Stripping grade and die size do not match.
v
Machine not in start position.
v
v
48
Recommended action
► Remove the ferrule (see section 8.6).
► Press touch display briefly.
► Insert the wire deeper.
► Press touch display briefly.
► Check the quality of the crimp.
► Close front flap.
► Press touch display briefly.
► Press touch display briefly
► Check the start switch for blockage.
► Insert the wire later
► Press touch display briefly
► Insert the connector slower.
► Send machine in for servicing.
► Correct drum position. Inching mode.
► Press touch display briefly.
► Move to start position. Inching mode.