2 PRODUCT DESCRIPTION
Models and contents of the package
The name GULLIVER identifies a series of electromechanical operators for industrial sliding gates with different features as to motor
and control board power supply voltage, capacity, mechanical adjustment of force and built-in limit switch.
GULLIVER is completed by a set of accessories listed in the "PRODUCT ACCESSORIES" table (page 118).This operator is composed of
a mechanical gear motor which rotates the driving gear; This gear, coupled to the rack properly installed on the gate, converts the circular
motion of the gear motor into rectilinear motion thus allowing the movement of the gate on its own guide.
Inspect the "Contents of the Package" (Pic. 1) and compare it with your product for useful consultation during assembly.
Transport
GULLIVER is always delivered packed in boxes that provide adequate protection to the product, however, pay attention to all informa-
tion that may be provided on the same box for storage and handling.
3 TECHNICAL DATA
Motor power supply voltage (V)
Absorbed power (W)
Max Thrust (N)
Duty cycle (cycles/hour)
Maximum n° of operations in 24 hour
Built-in capacitor (µF)
Operating temperature range (°C)
Motor thermal protection (°C)
Opening speed (m/min)
Weight of product with package (Kg)
Protection degree
Power supply (V)
Fuse F2 (A)
Fuse F1 (A)
230V operators outputs
Auxiliaries power supply output
"Warning" output
Electric lock output
230V Flashing light output
24V Flashing light output
Operating temperature range (°C)
Receiver frequency
Transmitters type of coding
Max remote controllers managed
4 INSTALLATION AND ASSEMBLY
4.1 For a satisfactory installation of the product is important to:
• Ensure that the facility complies with current regulations and then define the full project of the automatic opening;
• Ensure that throughout the course of the gate, while opening and closing, there are no friction points;
• Ensure that there is no danger of derailment and that there are not risks that it goes out of the guides;
• Make sure the gate is in equilibrium: it must not move if it stays in any position;
• Ensure that the mounting area of the motor allows the release and a manual operation easier and safer;
• Ensure that the mounting positions of the various devices are protected from impacts and the surfaces are sufficiently robust;
• Do not allow the automation parts are immersed in water or other liquids.
18
OPERATOR
18NET - 18NET/M - 18NET/IB - 1503E
230 V ~ ±10% (50/60 Hz)
560
875
15 (leaf L=12m)
240
30
140 °C
10
CONTROL BOARD
NET230N
230 V ~ ±10% (50/60 Hz)
max 1 art. 110 or 24V
24 V
max 100mA (for led flashing light) art. LED24AI or
open gate warning light/courtesy light
HCS fix-code - HCS rolling code - Dip-switch
25RRT - 22RRTF - 22RRT/M - 25RRT/IB
400 V ~ ±10% (50/60 Hz)
1200
1650
17 (leaf L=14m)
280
-20 ÷ 50 °C
10
30
IPX4
5A
160mA
2 x 600W
24 V ~ max 200mA
230 V ~ max 150W
output max 5W configurable
230 V ~ max 40W
-20÷50 °C
433,92 MHz
100
-
-