10 MAINTENANCE
Good preventive maintenance and regular inspection ensure
long working life. In the table below you will find a listo f inspections/
maintenance operations to be programmed and executed periodi-
cally.
Consult the TROUBLE-SHOOTING" table whenever anomalies are
observed in order to find the solution to the problem and contact
DEA System directly whenever the solution required is not provided.
Description
When the opening or closing command is activated the gate
leaf fails to move and the operator's electric motor fails to
start.
When the opening command is activated, the motor starts
but the gate leafs fail to move.
The gate moves by fits and starts, it is noisy, it stops at half
run or it does not start.
11 PRODUCT DISPOSAL
GULLIVER consists of materials of various types, some of which can be recycled (electrical cables, plastic, aluminum, etc. ..) while
others must be disposed of (electronic boards and components).
Proceed as follows:
1. Disconnect the power supply;
2. Disconnect and disassemble all the accessories connected. Follow the instructions in reverse to that described in the section "Installa-
tion";
3. Remove the electronic components;
4. Sorting and disposing of the materials exactly as per the regulations in the country of sale.
WARNING In line with EU Directive 2002/96/EC for waste electrical and electronic equipment (WEEE), this electrical product must
not be disposed of as unsorted municipal waste. Please dispose of this product by returning it to your local municipal collection
point for recycling.
28
INTERVENTION TYPE
cleaning of external surfaces
checking of screw tightening
checking of release mechanism operation
electric brake cleaning
TROUBLE-SHOOTING
The operator is not receiving correct power supply. Check all connections, fuses, and the
power supply cable conditions and replace or repair if necessary. If the gate does not close
check the correct functioning of photocells.
Check that the unlocking system is closed (see Pic. 7).
Check the electronic force adjustment device and the mechanical clutch.
Make sure that the motor does not push in the opposite direction, the limit switch electrical
connections might be reversed.
Make sure that nothing hinders the gate wheels movement and the slide in which they roll.
There always must be backlash between rack and pinion; make sure the rack is accurately
positioned.
The power of the gearmotor may be insufficient for the characteristics of the gate's wing;
check the choice of model whenever requiredh.
If the operator attachment to the gate bends or is badly fastened, repair and/or buttress it.
Possible solutions
PERIODICITY
6 months
6 months
6 months
6 months