4.2 Defined and satisfied these prerequisites, proceed to the assembly:
If the supporting plane is already available, the fixing of the motor must be done directly on the surface using, for example screw
anchors or chemical means.
Alternatively, proceed as follows:
• Make a hole appropriate to the type of land by using as a reference the measurements shown in Fig 3;
• Provide an adequate number of channels for the passage of electrical cables;
• Place the base of the foundation;
• Start casting of concrete and, before you start taking, bringing the base plate to the dimensions shown in Figure 4, making sure that
is parallel to the gate wing and perfectly level. Wait for the complete setting of the concrete;
If the rack is already present, place the pinion at a distance of 1-2 mm in order to avoid that the weight of the wing could burden
on the gear motor (Fig. 5). To do this, adjust the height of GULLIVER shimming the base in an appropriate manner and then tighten the
locking screws in a robust way (Fig. 6).
Alternatively, proceed as follows:
• Unlock the motor and fully open the door;
• Place the first section of the rack on the wing, making sure that the start of the rack corresponds to the top of the wing. Then attach
the rack to the leaf keeping a game of 1-2 mm from the pinion (Fig. 5);
• Cut off the excess part of the rack;
• Finally, move the door manually several times and verify that the alignment and the distance of 1-2 mm between the rack and pinion
is respected throughout the length;
• Tighten the locking screws of GULLIVER in a robust way (Fig. 6) and cover with plastic caps.
4.3 How to unlock the operator
Once you open the lock on the handle (protected by a plastic cover), the lever must be turned in the direction shown in Fig. 7, at this
point the operator is unlocked and the gate, in the absence of other obstacles is free in his movements. The reverse process, turn the
lever until it stops and closing of the lock (remember to protect the lock with the proper cover), keeps GULLIVER in working condition.
4.4 Limit-switches
Adjustment of the limit-switches
Some GULLIVER models provides a limit-switch whose intervention must be adjusted for each installation. DEA System provides two limit
switches cams (Fig. 8) that are installed on the rack of the gate and subsequently regulated in such a way as to ensure the functionality
and safety distances in opening and closing of the gate.
Keep in mind that when the limit switches trigger, the door will move to another 2-3 cm, and it's therefore suggested to fix the end of
stroke brackets at a sufficient distance from the mechanical stops.
Adjustment of the magnetic limit switch
Attach the mounting brackets to the magnets as shown in Figure 10, making sure to mount the LIGHT BLUE magnet at the closing limit
switch, the GREEN magnet at the end of the opening limit switch (Fig. 11). Connect the cable of the magnetic sensor which is colored
BROWN at the FCC 1 input (Closing Limit Switch 1) and the BLACK one at FCA 1 input (Opening Limit Switch 1) (Fig. 12);
WARNING Refer to control board instructions to correctly identify the limit switch inputs.
WARNING Incorrect installation of the magnets can be dangerous to people or things; observe the conditions prescribed in these
instructions.
Mount the magnetic sensor as shown in Fig. 9. The sensor must protrude from the bracket for supporting at least 30mm, in this way will
avoid any interference.
Adjust the magnets support brackets so as to maintain a distance from the sensor between 10 and 20mm;
WARNING Opening and closing magnets positions are referred to a standard installation (operator placed on the left of the gate). In
case of use of the parameter P063 (NET control boards only) for an inverted installation (operator on the right), the position of the
magnets must not be changed.
In case of combination with the control panel art. 400RR, and only if you have to reverse the direction of travel of the geared motor,
you will have to manually reverse the limit switch cables.