230 V = 2 kW
3
400 V = 4 kW
3
400 V = 6 kW
3
4.
Guide the cable (2) through the power supply open-
ing and into the housing, and secure it using the PG
screwed connection (1).
–
Recommended tightening torque: ≤ 6.0 Nm
5.
Connect the conductors to the terminal block (3).
6.
Fit the seal and connector housing, and install the four
hex screws.
–
Recommended tightening torque: ≤ 1.9 Nm
7.
Fit the rotary knob on the setting control.
6
Start-up
6.1
Starting up the electrical immersion heater
1.
Fill the domestic hot water cylinder.
2.
Check the inspection opening for leaks.
0020230754_00 0020230734 Installation instructions
L1 N
1
2
L3 L2 L1 N
3.
Install the insulating elements.
4.
Switch on the power supply.
5.
Use the setting wheel to set the temperature to which
you want to heat the electrical immersion heater.
1
2
7
7.1
If the water temperature in the cylinder rises above 95 °C,
L3 L2 L1 N
the safety cut-out (SCO) on the electrical immersion heater
switches off the power supply.
7.2
1
2
1.
Switch off the power supply.
2.
Remove the insulating elements from the electrical im-
mersion heater.
3.
Remove the rotary knob (5) from the setting control.
A
C
Troubleshooting
Function of the safety cut-out
Releasing the safety cut-out after shutdown
Caution.
Risk of material damage caused by over-
heating!
If the fault that caused the product to shut
down is not rectified, the product may be-
come damaged.
▶
Do not switch the safety cut-out back on
until the cause of the fault that triggered
the safety cut-out has been eliminated.
1
2
3
5
4
Start-up 6
B
11